108
Distance to Fault (DTF) Measurement
Mode
Internal
Resolution [R]
X-Axis:
Where R=Resolution (meters),
ε
r
=Dielectric Constant*,
∆
F= frequency
bandwidth
Y-Axis:
0.1 dB, 0.01 VSWR
Range
X-Axis:
Y-Axis:
238 x R
0 to –60 dB
Accuracy
X-Axis:
Y-Axis:
± 2% of full-scale range with V
p
= 1
Same as for Return Loss Measurements
V
p
Range
0.20 to 1.00, or 1.00 to 99 percent
(new specs)
Power Measure Mode
Function:
Displays power from Bird power sensors,
VSWR alarm and BPM
(specifications determined by sensor)
General
Data Storage
300 traces in fundamental data format
stored in non-volatile memory. Traces
may be recalled and displayed in any of
the display formats.
PC/Remote Power Sensor Interface Port
Connector:
Protocol:
Female DB-9, compatible with PC serial
port.
Serial RS-232, 9600 baud, 8 data bits, 1
stop bit, no parity, and no handshake.
R
3
8
×
10
2
ε
r
F
∆
×
×
-------------------------------
≡