Fault Location Mode
47
Limit Test
Limit Test compares the trace to the limit line.
Test Off —
disables the comparison and the pass/fail
indicator.
Test On —
enables the comparison. If all of the trace is
below the limit value, “PASS” is displayed at the
bottom of the screen. If any part of the trace exceeds
the limit value, that portion is displayed in red and
“FAIL” is displayed at the bottom of the screen.
Test Audio —
as Test On. In addition, the Site
Analyzer will beep if any part of the trace exceeds the
limit value.
Press from
Fault
Location
Mode
Toggle
between Off,
Audio, & On
0.0
Meters
18.2
Fault Location Mode
Calibration: Full
Limit: 1.43
FAIL
1.70
1.00
V
S
W
R
Save/
Recall
Auto
Scale
Limit
Test On
HOLD