Chapter 3
Installation
Location
Install the Model 8201 or 8203 Termaline Load Resistor in a location that:
Has sufficient room to provide at least six inches of free space around
and above the unit.
Is the shortest possible distance, or cable length from the transmitting
equipment.
Ensures the operation of the load in a horizontal position only, with the
handle on top.
Mounting
The load may be used for portable operation or for fixed installation, that is, it
may stand free or may be secured to a bench or any convenient flat surface. The
front and rear fins are made of heavier gauge material bent outward 90 degrees
to form mounting flanges. To fasten the load by means of its base mounting
flanges:
1.
Fasten the load with four screws. Put one screw in each of the four 9/32
inch holes.
Note:
Use screws up to 1/4 inch diameter. The holes are arranged
in a 5-1/8 x 12-17/32 inch rectangle (130.2 x 318.3 mm).
CAUTION
The load is designed for operation in a horizontal plane only, with mounting
brackets down. Do not operate in any other position.