7
Chapter 4
Operating Instructions
Normal Operation
Bird 8251 series loads have no indicators or operating controls. They require no special operating procedures or
surveillance when their performance limits are not exceeded. Follow the instructions for the specific transmitter
equipment.
Operating Under Abnormal Conditions
The load can be moderately overloaded for short periods.
Shutting Down
Note:
These loads are passive devices, so have no way of being turned off. Turn off RF power at the
source.
Emergency Shutdown
Turn off RF power at the source.
Note:
If the interlock thermoswitch is properly connected, RF power will be automatically turned off
when the coolant temperature reaches an unsafe level
WARNING
The vent plug must be used at all times when the unit is operating or cooling. Failure to do
so could result in an explosion or severe burns.
CAUTION
Make sure the interlock is properly connected when overloaded to prevent damage to the load.
WARNING
Never attempt to connect or disconnect RF equipment from the transmission line while RF
power is being applied. Leaking RF energy is a potential health hazard.