18
Installation Manual: BIPV Modules
17
Installation Manual: BIPV Modules
3�2� Flashing Profiles
Figure 10: Flashing profiles
1
Flashing profile left
2
Flashing profile right
3�2�6 Side Flashings
The flashing sides create a link between flashing profiles and roof tiles. The flashing tops ensure a transition between the top
module edge and the row of tiles that lies above it. They are designed in such a way that they are suitable for many conventional
types of roof tiles. In the event of other requirements (e. g. tiling bat tens and Solrif® battens at different levels, special types of
tiles, like slate, etc.) please contact BISOL Production Ltd and Ernst Schweizer AG.
Figure 11: Side flashings
Measurements height × width
L
H
= laminate height, L
B
= laminate width
1
Flashing side left
(L
H
+110) × 121
2
Flashing side top left
281 × 121
3
Flashing top left
281 × (L
B
+ 54)
4
Flashing top middle
281 × (L
B
+ 32)
5
Flashing top right
281 × (L
B
+ 54)
6
Flashing side top right
281 × 121
7
Flashing side right
(
L
H
+110) × 121
Notice
When using side flashings other than the original Solrif® side flashings, it must be checked whether