46
Installation Manual: BIPV Modules
45
Installation Manual: BIPV Modules
Figure 47: Push in flashing side right
1. In order to be able to draw a marking line, push a mounting clamp temporarily the wrong way around into the flashing
profile right.
Figure 44: Marking the position of the left-hand edge of the mounting clamp
Figure 45: Aligning the mounting clamp
Figure 46: Mounting the remaining mounting clamps
2. In doing so, ensure that the flashing profile right maintains a distance of 2 mm to the module frame.
3. Mark left-hand edge of the inserted mounting clamp on the batten.
4. Lay the mounting gauge onto the top edge of the right-hand module and align the mounting gauge to the line you just
marked.
5. Mount all the clamps for this module according to the roof plan with the aid of the mounting gauge.
6. Proceed in the same manner for the remaining mounting clamps in this row.
7. Push the flashing side right into the lower lying right-hand profile until it clicks into place.