48
Installation Manual: BIPV Modules
47
Installation Manual: BIPV Modules
Figure 51: Mounting clamps top row transitions
Figure 48: Push in the flashing profile right
Figure 49: Lay remaining modules
Figure 50: Mounting clamps top row edge
8. Push the flashing profile right into the mounting clamp profile.
9. Lay the second row of modules and connect the cables according to the string plan at the same time.
10. Mount the next row of mounting clamps.
11. Complete the PV array including side flashings and flashing profiles like in the bottom row.
Placing the top row mounting clamps:
12. Place the outside left-hand and the outside right-hand mounting clamps like in the rows below.
13. At the module transitions:
Do NOT place the Mounting Clamps Profile at the marked positions, rather place two Mounting Clamps Profile instead of
one, each one offset by 40 mm to the left and to the right respectively of the marking. Like in the rows below, maintain a
distance of 15 mm between the top edge of the module and the recess of the mounting clamp.