General Components Overview
1
Fkashing side left
2
Flashing profile left
3
BISOL BIPV module
4
Flashing profile right
5
Flashing side right
6
Wedge plank
7
Mounting Clamp Profile
8
Flashing top
L
B
Width of the laminate
L
H
Height of the laminate
M
B
Width of a single framed module = L_B + 50
M
H
Height of a single framed module = L_H + 32
R
hor
Rhor Horizontal module mounting pitch (distance of any reference point on the module to the same point on the module
mounted beside it to the right or left) = M
B
– 18
R
ver
Rver Vertical module mounting pitch (distance of any reference point on the module to the same point on the module
mounted above or below it) =
M
H
– 32
N
hor
Nhor Number of modules laid out side by side in the PV array
N
ver
Nver Number of modules laid out above each other in the PV array
B
GR
Width of the PV array between the flashing sides = (N
hor
× R
hor
) + 42
B
GL
BGL Width of the PV array including the flashing sides = (N
hor
× R
hor
) + 284
H
G
HG Height of the PV array between the lower edge of the bottom mounting clamp and the upper edge of the top mounting
clamp = (N
ver
× R
ver
) + 104
H
GB
HGB Height of the PV array between the lower edge of the bottom mounting clamp and the upper edge of the flashing tops
= (N
ver
× R
ver
) + 283
3�2�3 Substructure
Solrif® battens measuring 120 mm × 30 mm are used as a substructure, which are screwed onto the existing roof construction
instead of or in-between the roof battens to which the tiles were attached. Minimum requirements for wood quality: Strength
category C24.
Notice
Plan an extra 10 % for cutting losses compared to the batten plan. In addition, keep some spare wood to
hand to equalize out any unevenness in the roof construction or to be able to implement connections
or linings. A wedge plank is necessary for the bottom gutter of the PV array, see Chapter
„Wedge Plank“
.
The bottom row of Solrif® battens must extend beyond the flashing sides by at least 150 mm respectively as an overlay for the
lead flashing, i. e. the length of the bottom row of Solrif® battens must be at least B
GL
+ 300 mm.
All other rows of Solrif® battens must extend beyond the flashing sides by at least 50 mm respectively, i. e. the length of the
other rows of Solrif® battens must be at least B
GL
+ 100 mm respectively.
Figure 7: Substructure