16
Installation Manual: BIPV Modules
15
Installation Manual: BIPV Modules
3�2�4 Mounting Clamps
BISOL BIPV module with Solrif® frame are attached to the substructure with mounting clamps. There are three different types
of clamps:
Figure 8: Mounting clamps
Art. No.
Application
1
Mounting Clamp Profile
- raw, 1.4310
- black/browned, 1.4310
- raw seawater-resistant, 1.4404
13318
06497
13995
Fastens overlapping modules in the area of the profiles
left/right or flash ing tops; always required
2
Mounting Clamp Glass with protective shrink tubing
- raw, 1.4310
- black/browned, 1.4310
- raw seawater-resistant, 1.4404
13319
06500
13996
Fastens overlapping modules in the area of the open
glass edge; number according to structural analysis
requirements
3
Mounting Clamp Top
- raw, 1.4310
- raw seawater-resistant, 1.4404
33954
13997
For fastening the top row of modules when not using
regular flashings top
4
Wood screw with pan head 4.5×35 SST, with general
building inspectorate approval ETA/DIBt
(countersunk bolts may not be used)
61831
Notice
Danger of confusion!
Please be aware that the different types of clamps must be used positioned and in quantities as required
according to the roof plan.
Roof plan design needs to be done with PV planning software SPT (proSOLRIF design software SPT at
www.ernstschweizer.ch for calculating the number of mounting clamps required per module.)
Figure 9: Mounting clamps mounted
1
Mounting clamp profile mounted with the flashing tops
2
Mounting clamp profile for securing the module overlap or the overlap with flashing profiles
3
Mounting clamp glass for securing the bottom module edge