( Installing the unit (gasoline units)
Danger
Use the Airless spraying unit with a gasoline engine, preferably outdoors. Take the wind direction into account. Then place the unit so that no
vapors containing solvents are deposited in the area of the unit. Observe a minimum distance of 3 m between the unit with gasoline engine
and the spray gun. Observe a minimum distance of 3 m between the unit with gasoline engine and the spray gun.
( Using unit on construction sites (electric units) Connection to the mains only through a special feed point, e.g. through an error protection
insallation with INF < 30 mA
( Ventilation when spraying in rooms Adequate ventilation must be guaranteed in order to remove the solvent vapors and the exhaust fumes
of the gasoline engine.
( Suctions installations These are to be set-up by the user of the unit according to local regulations.
( Earthing of the object The object to be coated must be earthed.
( Cleaning the unit with solvents
Danger
When cleaning the unit with solvents, the solvent should never be sprayed or pumped back into a container with a small opening (bunghole).
An explosive gas/air mixture can arise. The container must be earthed.
( Cleaning the unit
Danger
Danger of short-circuits caused by water ingressing into the electrical equipment of the gasoline engine. Never spray down the unit with
high-pressure or high-pressure steam cleaners.
( Work or repairs on the electrical equipment Only have this work carried out by a qualified electrician. No liability will be taken for incorrect
installation.
( Working on electrical components Remove the power cord from the socket during all repair work.
Setting-up on uneven surfaces The front side of the unit must point downwards to prevent sliding away.
Italia Star Com Due S.R.L.
www.italiastar.ro
info@italiastar.ro
004/021.433.03.27
2. General view of application 2.1 Application
Priming and final coating of large areas, sealing, impregnation,
construction sanitation, façade protection and renovation, rust
protection and building protection, roof coating, roof sealing, concrete
sanitation, as well as heavy corrosion protection.
Examples of objects to be sprayed Large-scale construction sites,
underground construction, cooling towers, bridges, sewage treatment
plants and terraces. Generally for the whole building protection where
operation without electric power is required.
103