Replace dust bag
Never reuse a dust bag.
Use only BISSELL Style 7 Dust Bags in your BISSELL PowerForce.
Style 7 EnviroFresh
®
Micro Filtration Dust Bags (# 30861)
Style 7 Dust Bags (# 32120).
1.
Unplug cleaner from electrical outlet.
2.
Pull the bag door outward to open. Set bag door aside.
3.
Grasp dust bag collar, and pull collar from connector
tube. Discard used dust bag.
4.
Grasp new dust bag collar and push firmly onto
connector tube. Tuck in dust bag.
5.
Replace bag door by placing tab on bottom of door into opening
as shown. Press top of door to snap securely shut.
NOTE: Vacuum will not suction while the bag
door is removed.
Cleaning pre-motor & post-motor filters
Use only BISSELL Replacement Filters in your
BISSELL PowerForce.
1.
Unplug cleaner from electrical outlet.
2.
The pre-motor filter, located in the bottom of the bag
compartment, protects the motor from dirt particles. If
filter becomes dirty, lift out filter and clean.
3.
The post-motor filter assists in the filtration process to
return clean air to the room. To remove this filter, open
the door on the side of the cleaner. Grasp filter and pull
it straight out.
4.
The filters may be hand washed in cold water with
mild detergent, then air dried.
5.
Reposition filters when completely dry.
Check rotating floor brush and drive belt
You should check your vacuum cleaner’s rotating floor
brush and drive belt regularly for wear or damage. You
should also clean the brush and brush ends of string, hair, and carpet
fibers. These can wrap around the brush and hamper its ability to
effectively clean your carpet.
Also remove any debris that has
accumulated under the brush cover.
1.
Unplug cleaner from electrical outlet.
2.
Place handle in low position and turn vacuum cleaner
over so bottom side is up.
3.
Remove the four screws as shown with a Phillips head
screwdriver. Lift the brush cover off.
4.
Grasp rotating floor brush at both ends and lift.
8
w w w . b i s s e l l . c o m 8 0 0 . 2 3 7 . 7 6 9 1
M
aintenance and care
Post-Motor
Filter
WARNING:
Do not operate cleaner
with damp or wet filters or
without all filters in place.
Pre-Motor
Filter
WARNING:
To reduce the risk of
injury from moving
parts, turn off vacuum
cleaner and disconnect
Power Plug from
electrical outlet.
Brush
Cover
ug603-5577_3525_107.indd 8
ug603-5577_3525_107.indd 8
1/22/07 2:04:32 PM
1/22/07 2:04:32 PM