background image

 

 

BT-410 Operator Manual                                     6 

   

 

P/N : OPM(BT-410)EN 

Bistos Co.,Ltd 

Rev. 05(2013.04.12) 

Section 

Introduction 

 
 

2.1   

General 

 
This chapter provides a general description of the BT-410 monitor including: 

 

 

Brief Device Description 

 

Product Features 

 

Model Configurations 

 

2.2   

Brief Device Description 

 

This Head-worn light

 

is used for medical examination by fixing it on the head 

and illuminating with condensed light to the injured part.

 

This unit doesn't intend 

to contact directly to the patient's body and can be used for all medical field 
except ophthalmology.

 

All material is made of the light plastic, and is consist of 

mainbody and headband.

 

The main body is composed of a light source (LED), 

main frame, and battery pack.

 

O

ptional accessories are consist of an astral lamp 

for shadowless effect, and loupe (magnifying glass).

 

The battery uses a lithium-

ion rechargeable one, and using time is about 4 hours.

 

Full recharge takes about 4 

hours.

 

LED's optical power will be a little decreased even though you use the unit 

normally according to recommended using time.

 

The expectedly possible using 

time is for approximately 50,000 hours.

 

 

2.3 

  Intended Use 

 

The BT- 410 Head-worn light

 

allows doctors to examine with a clear eye onto 

the affected part by wearing it onto the head.   

 
2.4 

  Product Features 

 

  Battery pack can be separated, so separate recharging is possible

  You can check necessary recharging time with LED indicator of recharging status. 

  Irradiating to up & down and left & right side is possible by pivot joint. 

  Operation is very simple, so the unit is easy to use . 

 

2.5   

Product Configuration 

 

BT-410

 

system consists of the following elements. Open the packaging contains 

the following accessories, please check. Also check for any damage to your 

Summary of Contents for BT-410

Page 1: ...BT 410 Head worn light Operator Manual P N OPM BT 410 EN Rev 05 BT 410...

Page 2: ...is believed to be accurate and reliable However no responsibility is assumed by Bistos Corporation For its use or any infringements of patents or other rights of third parties that may result from it...

Page 3: ...Assembly and Operation 8 3 1 The overall panel 8 3 2 Loupe Optional Assembly 9 3 3 Astral Lamp Optional Assembly 10 4 Use Method 11 4 1 Adjustable headband 11 4 2 Turn on the power Method 11 4 3 Adju...

Page 4: ...nt and or user CAUTION An instruction that if not followed can result in a condition that could damage the light WARNING Do not attempt to connect or disconnect a power cord with wet hands Make certai...

Page 5: ...a where thereisan excessiveshockor vibration Avoid placing in an area where chemicals are stored or where there is in danger of gas leakage Avoid dust and especially metal material into the equipment...

Page 6: ...s and Symbols Symbol Description Requirements Stand by IEC TR 60878 This symbol identifies a safety note Ensure you understand the functions of these controls before using it Function controls are des...

Page 7: ...shadowless effect and loupe magnifying glass The battery uses a lithium ion rechargeable one and using time is about 4 hours Full recharge takes about 4 hours LED s optical power will be a little dec...

Page 8: ...05 2013 04 12 console and accessories please check If you wish to purchase please contact our office Part Name Part Name Main body Loupe Optional Charger Astral Lamp Optional User Manual Battery Pack...

Page 9: ...embly and Operation 3 1 The overall panel Fig 1 1 The overall panel Headband height adjustable part Headband part Headband size adjustable part Protect band Power On Off Button LED indicator Main Fram...

Page 10: ...10 EN Bistos Co Ltd Rev 05 2013 04 12 3 2 Loupe Optional Assembly BT 410 turn in front of our parts are assembled in the loupe In order to assemble the picture below Loupe assembled with optional Main...

Page 11: ...tos Co Ltd Rev 05 2013 04 12 3 3 Astral Lamp Optional Assembly BT 410 is located at the bottom of the astral lamp and pay off the lens cap from the bottom up by assembly In order to assemble the pictu...

Page 12: ...ation 4 4 Turn off the power Method The power switch once more to keep from pressing the button will turn off the lights 4 5 Adjust intensity of light only for Optional Main body User can adjust inten...

Page 13: ...tions such as separation of battery pack and its un separation However the equipment must be powered off to charge the battery un separated Please refer to the below as shown simply in order of how to...

Page 14: ...color to red or orange 4 8 Optional Features Loupe Optional Surgery or medical details by expanding the area used to be you And when not in use loupe loupe or a separation of 90 degrees by raising the...

Page 15: ...kewarm water 40 C 104 Kindly also wipe it with a clinical alcohol about once a week 5 3 Battery Disposal and Handling Be cautious when disposing of Lithium ion Battery pack Adhere to all applicable la...

Page 16: ...m working distance Color Temperature 6 000 Kelvin Lighting LED Life time 50 000 hours Headband Size 534 638 mm Weight 119 g Battery Pack Using the time 4 hours Rechargeable times 800 times Capacity 3...

Page 17: ...2 200mAh Charger Input Output Charging time AC 100 240 Vac 50 60 Hz 0 8 A DC 4 2 V 750 mA 4 hours Power Consumption 3 15 VA Environmental Operating Temperature 10 C to 40 C 50 F to 104 F Storage Temp...

Page 18: ...nty Period 2 Years Date of Purchase Customer Hospital Address Name Telephone Sales Agency Manufacture Bistos Co Ltd Thank you for purchasing BT 410 This product is manufactured and passed through stri...

Page 19: ...0340 Fax 82 31 750 0344 Bistos Co Ltd 7th Fl A Bldg Woolim Lions Valley 5 cha 144 3 Sangdaewon dong Jungwon gu Seongnam si Gyeonggi do Korea www bistos co kr bistos bistos co kr Model Name BT 410 EC R...

Reviews: