- 16 -
S19j Server Installation Guide
4. Monitoring Your Server
4.
Monitoring Your server
To check the operating status of your server:
1.
Click dashboard marked below to check the server status (taking S19j 90T as an example).
Note: The S19j server (90T) is with fixed frequency 550 MHz. Firmware will stop running when the Temp
(Outlet) reaches to 85
℃,
there will be an error message “over max temp, pcb temp (real-time temp)”
shown on the bottom of kernel log page. Meanwhile, the server temperature on the dashboard interface
turns to abnormal and shows “Temp is too high”.
2.
Monitor your server according to the descriptions in the following table:
Option
Description
Number of chips
Number of chips detected in the chain.
Frequency
ASIC frequency setting.
Real Hashrate
Real-time Hashrate of each hash board (GH/s).
Inlet Temp
Temperature of the inlet (°C).
Outlet Temp
Temperature of the outlet (°C).
Chip state
One of the following statuses will appear:
●
The Green Icon - indicates normal
●
The Red Icon- indicates abnormal