background image

BITMAIN

S7 Server

 Manual

 

Summary of Contents for AntMiner S7

Page 1: ...BITMAIN S7 Server Manual ...

Page 2: ...atures 4 3 Power Supply 4 4 Connect to server 6 5 Server Configuration 8 5 1 Pool Setting 8 5 2 Frequency Modification 8 6 Server Status 9 7 System Configuration and status 9 7 1 System Upgrading 9 7 2 Password Modification 10 7 3 Software Version Checking 11 7 4 Restore Initial Setting 11 ...

Page 3: ...using the new state of the art BM1385 chip with full customs made powered by ultra low power 28nm technology It s with several different hash rate and the final one is 4 73th s S7s are tested and configured prior to shipping to make it easier for customers to set up Please note 1 You must prepare your own ATX Power Supply ...

Page 4: ...ll required on each hash board and there is no DC DC inside the server Higher input voltage will cause higher working efficiency 3 Power Supply Each S7 Server has 9 PCI e connectors for 12V 15A DC STABLE input on hash boards and 1 PCI e connector on the controller all the 10 PCI e connectors are required Do not connect more than one PSU to the same hashing board to prevent possible damage and inst...

Page 5: ...S7 Server Manual Last updated 2 1 2016 Page 5 of 12 Page 5 12 ...

Page 6: ...e follow below steps to find out the IP of the server 1 Extract the file and double click IPReporter exe The Shelf Step Position options are suitable for farm servers to mark the location of the servers For home servers it can be left as default Then click Start 2 Press the IP Reporter button on IO board and you ll hear a beep sound 3 Check your PC you ll see the IP address showing in the pop up w...

Page 7: ...of 12 Page 7 12 Step 2 Enter the IP address provided into your WEB browser and proceed to login using root for both the username and password In the Network section you can assign a Static IP address if you like Click Save Apply after modifying it ...

Page 8: ...ols with low priority will only be used if all higher priority pools have gone offline 4 1 2 When Stop running when temperature is over 80 is checked the server will stop running when the temperature exceeds 80 to protect the server If it s unchecked the server will still run even in high temperature 4 1 3 When Customize the fan speed percentage is checked the fan speed can be controlled by custom...

Page 9: ...tus of your server on the page marked below ASIC Number of chips detected in the chain Frequency ASIC frequency setting Temp Temperature centigrade ASIC status o stands for OK x stands for error 7 System Configuration and status 7 1 System Upgrading You can upgrade the server s firmware on System Upgrade page ...

Page 10: ...ed and download the software During the upgrade process you need to wait patiently and must keep power on otherwise the server can only be fixed with returned to factory You will see below screenshot after upgrading successfully Clicking the Reboot button will restart the server so it can load the new software Clicking Go Back will keep the server running before switching to the new software when ...

Page 11: ...server use In the example below the S7 Server is using 20150915 firmware 7 4 Restore Initial Setting There is a Reset button on the right hand side of the Ethernet port next to the green and red LED light Power on server and let it run for 5 minutes then press and hold the reset button for 10 seconds in order to restore to the default settings and reboot The red LED will flash once every 15 second...

Page 12: ...Page 12 12 S7 Server Manual Last updated 2 1 2016 Page 12 of 12 ...