background image

S5 

Server 

Manual

Last updated: 3/26/2015

Page 8 of 11

Page 8 / 11 

software  will  take  approximately  10  seconds  to  connect  to  the  server,  and  then  the  client 

software continues to  run  after settings are saved. If either the Off/On  is selected  to  ‘OFF’ or 
the UID is left blank,  

‘Link’

 will remain disabled.

4.3.4

 

Once ‘Link’ is enabled, the ‘Addr’ will become fixed and cannot be updated by 

customers. This refers to Bitmain’s monitoring server address. 

6

 

Server Status 

You can check the operating status of your server on ‘Status’ page. 

ASIC#: Number of chips detected in the chain 
Frequency: ASIC frequency setting 
Temp: Temperature, centigrade 
ASIC status: o stands for OK, x stands for error. 

Summary of Contents for S5

Page 1: ...BITMAIN S5 Server Manual ...

Page 2: ...er Supply 4 4 Connect to Server 4 5 Server Configuration 7 5 1 Pool Setting 7 5 2 Frequency Modification 7 5 3 Server Link Connection 7 6 Server Status 8 7 System Configuration and status 9 7 1 System Upgrading 9 7 2 Password Modification 9 7 3 Software Version Checking 10 7 4 Restore Initial Setting 10 ...

Page 3: ...pare your own ATX Power Supply 2 Features Ideal Hash Rate GH s 1155 Default chip clock M 350 Input Voltage V 12 00 12 50 Typical Input Current A 45 Typical Input Power W 540 Estimate power on wall W assume AC DC efficiency is 90 590 Estimate efficiency on wall W GH 0 51 Dimensions mm 298 x 137 x 155 Weight kg 3 5 Operating ambient temperature C 0 35 Notes Input voltage should not be less than 12 0...

Page 4: ... and INCORRECT connection of the PCI E connectors Correct connection Incorrect connection 4 Connect to Server Step 1 The default DHCP network protocol distributes IP addresses automatically Please download IPReporter zip from serverlink com then please follow below steps to find out the IP of the server 1 Extract the file and double click IPReporter exe The Shelf Step Position options are suitable...

Page 5: ...5 Server Manual Last updated 3 26 2015 Page 5 of 11 Page 5 11 2 Press the IP Reporter button on IO board and you ll hear a beepsound 3 Check your PC you ll see the IP address showing in the pop upwindow ...

Page 6: ... of 11 Page 6 11 Step 2 Enter the IP address provided into your WEB browser and proceed to login using root for both the username and password In the Network section you can assign a Static IP address if you like Click Save Apply after modifying it ...

Page 7: ...e server stopsmining 4 1 3 When Stop running when temperature is over 80 is checked the server will stop mining when the temperature exceeds 80 to protect the server If it s unchecked the server will still mine even in high temperature Click Save Apply to save and restart server 5 2 FrequencyModification You are able to modify the frequency value through Advanced Settings marked below The default ...

Page 8: ...cted to OFF or theUID is left blank Link will remain disabled 4 3 4 Once Link is enabled the Addr will become fixed and cannot be updated by customers This refers to Bitmain s monitoring server address 6 Server Status You can check the operating status of your server on Status page ASIC Number of chips detected in the chain Frequency ASIC frequency setting Temp Temperature centigrade ASIC status o...

Page 9: ...ton The interface will display if the firmware can be upgraded and download the software During the upgrade process you need to wait patiently and must keep power on otherwise the server can only be fixed with returned to factory Youwill see below screenshot after upgrading successfully Clicking the Reboot button will restart the server so it can load the new software Clicking Go Back will keep th...

Page 10: ...the date of the firmware your server use In the example below the server is using 20141218 firmware 7 4 Restore Initial Setting There is a Reset button on the right hand side of the Ethernet port next to the green and red LED light press and hold the button for 5 seconds in order to restore to the default settings and reboot The red LED will flash once every 15 seconds automatically if the reset i...

Page 11: ...S5 Server Manual Last updated 3 26 2015 Page 11 of 11 Page 11 11 ...

Reviews: