T19 Hydro Server Installation Guide
- 12 -
Note: The frequency of T19 Hydro server is fixed with the value 550 MHz. Firmware will stop running when
the Temp (PCB) reaches to 80
℃
or the water temperature is either greater than 65
℃
or lower than 20
℃
,
there will be an error message “Fatal Error: Temperature is too high!” shown on the Bottom of the Kernel log
page.
4. Monitoring Your Server
4.
Monitoring Your Server
To check the operating status of your server (taking T19 Hydro 138.5T as an example):
1.
Click dashboard marked below to check the server status.
2.
Monitor your server according to the descriptions in the following table:
Option
Description
Number of chips
Number of chips detected in the chain.
Frequency
ASIC frequency setting.
Real Hashrate
Real-time Hashrate of each hash board (GH/s).
Inlet Temp
Temperature of the inlet (°C).
Outlet Temp
Temperature of the outlet (°C).
Chip state
One of the following statuses will appear:
●
The Green Icon
- indicates normal
●
The Red Icon
- indicates abnormal