TECHNICAL INFORMATION & SUPPORT 

 

 

 

 

CHARACTERISTICS 

• Electronic command device for independent mounting 
• Relay ............................. 250V 5A cos(

Φ

)=1 resistive load NC/COM/NO 

• Temperature sensor ...... Accuracy ±0.5°C, resolution 0.1°C 
• Radio system................. ZigBee Home Automation 1.2 - 2.4 GHz 
• Encrypted communication, regular connectivity test, battery warning 
• Power supply................. 2 Alkaline AA type batteries 
• Battery lifetime............... ca. 2 years depending on usage profile 
• Operating temperature .. -10 - to 60°C 
• Humidity ........................ Up to 85% non-condensing 
• Dimensions.................... 85 x 85 x 24 mm  
• Case protection class .... IP30 
• Action type and complimentary action type 1.C 
• Isolation class II, high voltage cl. II, pollution cl. 2, software cl. A 
• Compliant with directives 2006/95/CE, 89/336/EEC, 99/5/EEC 

 

In order to use this product with QIVICON, you need a QIVICON Home 
Base with a QIVICON ZigBee radio dongle. 

 

Für die Verwendung dieses Produkts mit QIVICON benötigen Sie über 
eine mit einem QIVICON ZigBee Funkstick ausgestattete QIVICON Home 
Base. 

 

SUPPORT 

In case of connection problems, we advise to use smart plugs in order to 
increase the range of the ZigBee radio network. For further information 
and for product support, please consult 

http://support.bitronvideo.eu

 

LEGAL 

Subject to modifications and mistakes. The product is compliant with the 
CE requirements and further relevant standards. You may download the 
declaration of conformity at support.bitronvideo.eu or request a copy 
through our support. 
 

MANUFACTURER 

BITRON VIDEO 

Bitron Video s.r.l. 
Via Cimarosa 39 – 10154 Torino Italy 
www.bitronvideo.eu – info@bitronvideo.eu 
 
DS902010-018A 

LBT90373 

MADE IN ITALY

 

 

 

ENGLISH 

FUNCTION 

The thermostat allows you to manage a heating or cooling system using 
the built-in relay. The temperature threshold value can be set either 
manually using the buttons or automatically by the smart home system. 

 

SECURITY ADVISE 

Depending on the heating system it is possible that the conductors to and 
from the heating system mains voltage. In this case the installation of the 
thermostat needs to be carried out by an electrician. In any case we 
advise to disconnect the entire home from mains power before the 
installation (master switch). As the heating system is most probably 
connected to a separate circuit it is not sufficient to remove power only in 
the room where the thermostat is going to be installed. 

 

INSTALLATION 

Please follow for these guidelines for the correct positioning of the 
thermostat (fig. 3): 

ƒ

 

Position the thermostat at a position which is typical for the area to 
be managed (e.g. living room, sleeping room, bathroom). 

ƒ

 

Wall-mount the device at about 1.5 m. 

ƒ

 

Avoid direct sunlight. 

ƒ

 

Do not expose the thermostat to airflow (door/window) or to warm 
objects (radiators). 

 

This step requires that you have a QIVICON Home Base equipped with a 
QIVICON ZigBee radio dongle. 

 

1.  Open the case by light pressure with a flat screwdriver on the strap 

at the center bottom surface and slide away the mounting base. 

2.  For your security, disconnect the heating system from mains power 

and ensure the contacts do not carry electric tension. 

3.  Open the protective cover using a cross screwdriver (fig. 2). The relay 

can operate in normally open (NO+COM) or normally closed 
(NC+COM) mode. Standard is NC which means that the heating system 
will be enabled by closing the relay and disabled by opening the relay. 
COM is the common contact for both settings. Ensure that the cables 
are well connected and close the cover. In case the heating system 
provides 3 wires for the connection of the thermostat do only connect 
the two switch conductors, the ground wire remains unused. 

4.  Fix the mounting base on the wall and insert the AA batteries 

following the polarity indicated. Now close the case (fig. 1). 

5. 

Follow the indications for the addition of new devices of the installation 
wizard, which can be found in the app or in the web interface of your 
QIVICON system. For further information on the registration process, 
please consult http://support.bitronvideo.eu.

 

OPERATION 

In standby mode the display will show the current temperature measured 
by the thermostat. The desired temperature can be set either manually by 
pressing the 

 (decrease) or 

+

 (increase) button or automatically through 

suitable apps for the QIVICON system. When setting the temperature and 
when the QIVICON system transmits a new temperature value to the 
thermostat, SET will be shown on the display (fig. 4). 
 
The status of the relay (heating, cooling, fan) is indicated by an icon in the 
left part of the display (fig. 4). If no icon is shown, the relay is in off mode. 
 
In case of low battery, the battery icon will be shown on the left bottom of 