TECHNICAL INFORMATION & SUPPORT
CHARACTERISTICS
• Electronic command device for independent mounting
• Relay ............................. 250V 5A cos(
Φ
)=1 resistive load NC/COM/NO
• Temperature sensor ...... Accuracy ±0.5°C, resolution 0.1°C
• Radio system................. ZigBee Home Automation 1.2 - 2.4 GHz
• Encrypted communication, regular connectivity test, battery warning
• Power supply................. 2 Alkaline AA type batteries
• Battery lifetime............... ca. 2 years depending on usage profile
• Operating temperature .. -10 - to 60°C
• Humidity ........................ Up to 85% non-condensing
• Dimensions.................... 85 x 85 x 24 mm
• Case protection class .... IP30
• Action type and complimentary action type 1.C
• Isolation class II, high voltage cl. II, pollution cl. 2, software cl. A
• Compliant with directives 2006/95/CE, 89/336/EEC, 99/5/EEC
In order to use this product with QIVICON, you need a QIVICON Home
Base with a QIVICON ZigBee radio dongle.
Für die Verwendung dieses Produkts mit QIVICON benötigen Sie über
eine mit einem QIVICON ZigBee Funkstick ausgestattete QIVICON Home
Base.
SUPPORT
In case of connection problems, we advise to use smart plugs in order to
increase the range of the ZigBee radio network. For further information
and for product support, please consult
http://support.bitronvideo.eu
.
LEGAL
Subject to modifications and mistakes. The product is compliant with the
CE requirements and further relevant standards. You may download the
declaration of conformity at support.bitronvideo.eu or request a copy
through our support.
MANUFACTURER
BITRON VIDEO
Bitron Video s.r.l.
Via Cimarosa 39 – 10154 Torino Italy
www.bitronvideo.eu – info@bitronvideo.eu
DS902010-018A
LBT90373
MADE IN ITALY
ENGLISH
FUNCTION
The thermostat allows you to manage a heating or cooling system using
the built-in relay. The temperature threshold value can be set either
manually using the buttons or automatically by the smart home system.
SECURITY ADVISE
Depending on the heating system it is possible that the conductors to and
from the heating system mains voltage. In this case the installation of the
thermostat needs to be carried out by an electrician. In any case we
advise to disconnect the entire home from mains power before the
installation (master switch). As the heating system is most probably
connected to a separate circuit it is not sufficient to remove power only in
the room where the thermostat is going to be installed.
INSTALLATION
Please follow for these guidelines for the correct positioning of the
thermostat (fig. 3):
Position the thermostat at a position which is typical for the area to
be managed (e.g. living room, sleeping room, bathroom).
Wall-mount the device at about 1.5 m.
Avoid direct sunlight.
Do not expose the thermostat to airflow (door/window) or to warm
objects (radiators).
This step requires that you have a QIVICON Home Base equipped with a
QIVICON ZigBee radio dongle.
1. Open the case by light pressure with a flat screwdriver on the strap
at the center bottom surface and slide away the mounting base.
2. For your security, disconnect the heating system from mains power
and ensure the contacts do not carry electric tension.
3. Open the protective cover using a cross screwdriver (fig. 2). The relay
can operate in normally open (NO+COM) or normally closed
(NC+COM) mode. Standard is NC which means that the heating system
will be enabled by closing the relay and disabled by opening the relay.
COM is the common contact for both settings. Ensure that the cables
are well connected and close the cover. In case the heating system
provides 3 wires for the connection of the thermostat do only connect
the two switch conductors, the ground wire remains unused.
4. Fix the mounting base on the wall and insert the AA batteries
following the polarity indicated. Now close the case (fig. 1).
5.
Follow the indications for the addition of new devices of the installation
wizard, which can be found in the app or in the web interface of your
QIVICON system. For further information on the registration process,
please consult http://support.bitronvideo.eu.
OPERATION
In standby mode the display will show the current temperature measured
by the thermostat. The desired temperature can be set either manually by
pressing the
–
(decrease) or
+
(increase) button or automatically through
suitable apps for the QIVICON system. When setting the temperature and
when the QIVICON system transmits a new temperature value to the
thermostat, SET will be shown on the display (fig. 4).
The status of the relay (heating, cooling, fan) is indicated by an icon in the
left part of the display (fig. 4). If no icon is shown, the relay is in off mode.