background image

Pour the coolant into the reservoir via the water filling hole. Once the reservoir is 90% full,

turn on the power supply for the pump to run and let the air exit the loop. Turn off the

power supply when the reservoir is near empty. Repeat until all the air has exited the loop.

Notice : Do not turn on the pump if the reservoir is empty.
                Bitspower recommends that consumers add the Bitspower coolant or 
                purified water for their water-cooling liquid. If the consumer chooses
                different  water-cooling  liquids , the  resulting  impurities  may cause
                peeling of the coating on some of the hardware, water channels block-
                age by built-up residue, improper operation of the water pump, water
                tank tube breakage, and o-rings deformation leading to leakage. Any
                issues related to the use of inappropriate water-cooling liquid will be
                the responsibility of the consumer.
                

BPTA-EFW
It is recommended to install the water-exhaust 
fitting at the lowest point of the water cooling 
system.

Step 1
Unscrew the top of the water-exhaust fitting.

AIO_PUMP

PUMP

 HEADER

① 

PWM CONTROL

CPU_FAN

PUMP

 HEADER

FULL

 SPEED

AIO_PUMP

① 

PWM CONTROL

CPU_FAN

A Negative electrode -
B positive ele
C Speed signal

A B C D

Step 2
Replace with the water-exhaust part. When 
screwing in the part, water will start to 
discharge, it is recommended to connect 
tubing beforehand to control the water outflow.

—  4  — 

III. BPTA-O11D-AK

Water filling hole

backplate / control panel / top cover 

90% full

Pump Spec.

Rated voltage:12V DC
Power consumption:8.4W
Maximum flow:460±15%L/h
Noise:≦24dBA
PWM:Yes
MTBF:≦15,000 hours
Warranty:2 years

BP-BB2WP-P02

Before installing the water cooling parts 
for the graphics card, please cut the soft 
tube as shown in the figure and remove 
the BP-BB2WP-P02.

Summary of Contents for TITAN X

Page 1: ...n Guide CPU Water Block A B 1 B 2 B 4 B 5 B 6 A 1 A 2 B 3 The allowable variance in tube length is 2mm 1 pc BPTA CPUMS V2 SKA A 1 A 2 Fittings B 4 pcs BPTA DOTFH1622 B 1 2 pcs TA F61 B 2 2 pcs BPTA F95 B 3 2 pcs BP RIGOS5 B 4 2 pcs TA F60 B 5 2 pcs TA F40 B 6 Accessory C 2 pcs Hard tube C 1 1 pc Fitting soft tube C 2 A B C CPU set C 3 Hard Tube C 1 Fitting soft tube C 2 V4 SCM3FL20 SPRING SCM3F6 1...

Page 2: ...springs should be slightly compressed with visible gaps in the spring coils Over tightening may result in poor contact between the water block and CPU Use an appropriate amount of Thermal Compound high end Bitspower cooling products are now available at microcenter com The CPU water block has a DRGB cable which can be connected to the DRGB extension cable of the radiator fans Bitspower Fan and DRG...

Page 3: ...d AMD 48x263 mm 48x263 mm Installation 1 Installation 2 Model Brand 1 B450 TOMAHAWK AM4 ATX MSI 2 B450 AORUS PRO WIFI AM4 GIGABYTE 3 X570 AORUS ELITE WIFI GIGABYTE CPU TUBE Motherboard AMD 48x263 mm 48x263 mm B 4 B 1 C 1 C 1 B 4 B 1 B 6 PUMP HEADER FULL SPEED AIO_PUMP PUMP HEADER PWM CONTROL CPU_FAN II AMD Chipset Installaiton How to install tubes for CPU ...

Page 4: ... to the use of inappropriate water cooling liquid will be the responsibility of the consumer BPTA EFW It is recommended to install the water exhaust fitting at the lowest point of the water cooling system Step 1 Unscrew the top of the water exhaust fitting AIO_PUMP PUMP HEADER PWM CONTROL CPU_FAN PUMP HEADER FULL SPEED AIO_PUMP ROL CPU_FAN A Negative electrode B positive electrode C Speed signal A...