SRP-F310/312
Rev. 1.01
BIXOLON
- 12 -
DLE EOT
Function:
Transmit real-time status
Code:
ASCII
DLE EOT
n
Hex
10
04
n
Decimal
16
4
n
Range:
1 ≤ n ≤ 4
Default:
None
Description:
This command enables commands to be operable in real-time.
This command transmits the printer-related status specified by n as follows:
n
Function
1
Transmit printer status
2
Transmit off-line status
3
Transmit error status
4
Transmit paper roll sensor status
■
Printer transmits the following status
n=1: Printer status
Bit
Binary
Hex
Decimal
Status
0
0
00
0
Not used. Fixed to Off
1
1
02
2
Not used. Fixed to On
2
0
00
0
Drawer kick-out connector pin 3 is LOW
1
04
4
Drawer kick-out connector pin 3 is HIGH
3
0
00
0
Online
1
08
8
Offline
4
1
10
16
Not used. Fixed to On
5
0
00
0
Not used. Fixed to Off