SRP-F310/312
Rev. 1.01
BIXOLON
- 66 -
Remarks:
■
If the number of the key code exceed 40, the key code is transmitted dividing up to 40.
- The status if the continuous transmission data block is present is 41H.
- The status if the continuous transmission data block is not present is 40H.
■
After the [Header-NULL] is transmitted, the printer receives a response from the hosg; then it performs the process
defined by the response.(See the tables below.)
- When the status (existence of the next data block) is Hexadecimal = 41H / Decimal = 65)
Response
Process performed
ASCII
Decimal
ACK
6
Transmits the next data
NAK
21
Transmits the previous data again
CAN
24
Ends the process.
- When the status (for the last data block) is Hexadecimal = 40H / Decimal = 64)
Response
Process performed
ASCII
Decimal
ACK
6
Ends the process
NAK
21
Transmits the previous data again
CAN
24
Cancels the process.
Differences:
None