Installation
Instruction manual GSP
26 / 92
38107010002 en-US
Measures for suppressing interference:
With severely contaminated mains supplies (e.g. when "thyristor-controlled systems" are
used) measures must be taken on-site to suppress interferences, e.g.:
– A separate supply line must be planned for Bizerba machines.
– In problem cases, install capacitively decoupled isolating transformers or other suppres-
sors into the supply mains prior to Bizerba machines.
Availability of the power plug used as a supply circuit disconnect
Make sure that any access point allows you to check whether the plug is disconnected.
4.2.3
Leveling
In order to ensure the scale's accuracy, machine must be installed horizontally.
Leveling of GSP H Flex
Turn feet of machine until air bubble is in
the center of the spirit level
.
Machine
is installed horizontally.
Fig. 10: Leveling
Re-level scale after each change of location.
Summary of Contents for GSP H
Page 1: ...Slicer GSP H GSP HD Instruction manual 38107010002 en ...
Page 11: ...Instruction manual GSP About this machine 38107010002 en US 11 92 ...
Page 15: ...Instruction manual GSP About this machine 38107010002 en US 15 92 ...
Page 88: ...Attachment Instruction manual GSP 88 92 38107010002 en US 10 Attachment ...