Operation
Operating instructions iS10 / iS20
40
38019417000 en
5
5.12.3
Net weighing with tare balance
Taring with weighed tare value.
Key
Display presentation
Process description
Requirements: The scale is in equilibri-
um. Weight value is within weighing
range.
If
is assigned with the relevant function, net weighing with fixed tare value is also
5.12.4
Deleting tare
Key
Display presentation
Description on how to proceed
Display of net weight.
Display of gross weight.
5.12.5
Counting operation
Key <F1> is assigned with "Cnt" and a reference number such as e.g. 10 is pre-selected,
see page 25.
The device also serves as:
–
Reference weight scale
Reference weight = weight of reference weight mass / number of reference parts
–
Quantity scale
Number of pieces = weight of mass to be counted / reference weight
In order to calculate the reference weight accurately, the following lower limit applies to the
reference mass:
Reference weight mass ≥ weighing range / 600