Examples of operating procedures
Operating instructions iS10 / iS20
96
38019417000 en
10
Remove (last) item x from carton.
Recording of (last) item x with data out-
put to PC/EDP or printer.
10.2
Counting, recording, totaling
Recording of single weight/number of pieces and total quantity/number of pieces with data
output to PC/EDP or a printer.
Added weighing counting, recording, totaling
Parameter settings
Counting function with reference number
10
Operating procedures
Scale is unloaded, set to 0
and total
memory is deleted.
Place carton on scale.
Tare scale to 0.
Fill 10 reference parts into carton.
Start counting with calculation of refer-
ence weight.
Number of pieces = reference number