background image

BJ-214 

BJ Enabler Alarm 

User guide 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
 
 
 
 
 
 
 
 
 
 
 
 

                              

www.bjliveat.com

 

 

 

The BJ Enabler Alarm allows activating an emergency 
alert. To activate the alarm you can use a switch or a 
BJ  System  controller.  This  device  uses  radio 
frequency signals. 
It is possible to choose from 4 different signal tones 
and plug an appliance into the socket. The appliance 

does not depend on the Enabler’s status. 

Fig.1: BJ Enabler Alarm

 

 
 
 
 

 
 
 

A) Using BJ System remote controllers 

To activate remotely the alarm using the BJ System 
controllers follow these steps: 

1.

 

Select  a  position  on  the  Enabler’s  “RF  code 
selector” (Figure 1). The code assigned to the 
Enabler is given by Table 1. A different melody 
is assigned to each selector position.  

2.

 

Connect  the  enabler  to  the  mains,  taking  into 
account the device’s technical characteristics.  

3.

 

Program on the controller the RF code assigned 
in  step  1  (check  the  controller’s  User  Guide  to 
carry out this operation).

 

 

4.

 

Press  the  button  on  the  controller  to  activate 
the  alarm.  Once  it  is  activated,  the  beep  will 
sound for a few seconds. 

 

Table 1 

 

Activating various enablers at the same time: 

It  is  possible  to  activate  various  Enablers  located  in 
different  places  at  the  same  time  by  adjusting  the 
“RF  code  selector”  to  the  same  position  in  all  of 
them. 

Activating different enablers: 

It  is  possible  to  activated  different  Enablers  by 
pressing  a  different  button  on  the  BJ  System 
controller. You just need to adjust a different position 
on the “RF code selector” in each Enabler. 

 

 

 

 

 

Power supply 

230~ / 50Hz 

Maximum power supply 

250V~ 

RF working frequency 

433 MHz 

Dimensions 

105x59x50 mm 

Socket for 3.5-mm mono female jack switch 

Selector 

4 to 9 

RF Code

 

25 

26 

27 

28 

Function 

Tone 1  Tone 2  Tone 3  Tone 4  Not used 

1. Description of the device

 

2. Technical data

 

3. Operating instructions 

 

IMPORTANT

:

  

Whenever  the  position  of  the  “RF  code 
selector” is modified to assign a different code 
to  the  Enabler,  it  must  be  unplug  from  the 
mains socket for at least 

5 seconds

. The new 

code will be recorded when the Enabler is plug 
again.

 

Switch

input

RF Code selector

Mains plug

Socket

Sound output