background image

TEST INSTRUMENT SAFETY

WARNING

1. 

There  is  little  danger  of  electrical  shock  from  the  dc  output  of  this  power  supply.  However,  there  are  several  other  possible  test 
conditions using this power supply that can create a high voltage shock hazard:

a.

 If the equipment under test is the "hot chassis" type, a serious shock hazard exists unless the equipment is unplugged (just 

turning off the equipment does not remove the hazard), or an isolation transformer is used.

b.

 If the equipment under test is "powered up" (and that equipment uses high voltage in any of its circuits), the power supply 

outputs  may  be  floated  to  the  potential  at  the  point  of  connection.  Remember  that  high  voltage  may  appear  at  unexpected 
points in defective equipment. Do not float the power supply output to more than 100 volts peak with respect to chassis or 
earth ground.

c.

 If the equipment under test is "off" (and that equipment uses high voltage in any of its circuits under normal operation), 

discharge  high-voltage  capacitors  before  making  connections  or  tests.  Some  circuits  retain  high  voltage  long  after  the 
equipment is turned off.

2. Use only a polarized 3-wire ac outlet. This assures that the power supply chassis, case, and ground terminal are connected to 

a good earth ground and reduces danger from electrical shock.

3. Don't expose high voltage needlessly. Remove housings and covers only when necessary. Turn off equipment while making 

test connections in high-voltage circuits. Discharge high-voltage capacitors after removing power.

(Continued on inside back cover)

Normal  use  of  test  equipment  exposes  you  to  a  certain  amount  of  danger  from  electrical  shock  because  testing  must 

sometimes be performed where exposed high voltage is present. An electrical shock causing 10 milliamps of current to pass 
through the heart will stop most human heartbeats. Voltage as low as 35 volts dc or ac rms should be considered dangerous 
and hazardous since it can produce a lethal current under certain conditions. Higher voltages are even more dangerous. Your 
normal  work  habits  should  include  all  accepted  practices  to  prevent  contact  with  exposed  high  voltage,  and  to  steer  current 
away from your heart in case of accidental contact with a high voltage. Observe the following safety precautions:

Summary of Contents for 1671A

Page 1: ...INSTRUCTION MANUAL MODEL 1671A INSTRUCTION MANUAL MODEL 1671A Triple Output DC POWER SUPPLY...

Page 2: ...Some circuits retain high voltage long after the equipment is turned off 2 Use only a polarized 3 wire ac outlet This assures that the power supply chassis case and ground terminal are connected to a...

Page 3: ...Instruction Manual For Model 1671A Triple Output DC POWER SUPPLY B K Precision Corporation 22820 Savi Ranch Parkway Yorba Linda California 92887...

Page 4: ......

Page 5: ...Operation 7 Variable Voltage Output 7 Typical Constant Voltage Output 8 Setting Current Limit 8 Typical Constant Current Operation 8 Page Constant Voltage Current Characteristics 9 12 Vdc Output 9 5 V...

Page 6: ...ii...

Page 7: ...mps each One common application for these power supply is powering of circuit boards while troubleshooting Many circuit boards require two or three input voltages with the most common values being 5 v...

Page 8: ...LINE REGULATION 108 TO 132 VAC 0 05 10 mV RIPPLE AND NOISE 5 mV rms CONSTANT CURRENT MODE LOAD REGULATION 0 4 10 mA LINE REGULATION 108 TO 132 VAC 0 4 10 mA RIPPLE AND NOISE 10 mA rms PROTECTION Curr...

Page 9: ...N 1 RIPPLE AND NOISE 5 mV rms PROTECTION Short circuit protection thermal overload protection OUTPUT NO 3 VOLTAGE Fixed 5 VDC 5 CURRENT 0 to 500 mA continuous POLARITY Positive or Negative CONNECTORS...

Page 10: ...fluctuation up to 10 of normal voltage DIMENSIONS H x W x D 4 9 x 8 5 x 11 5 124 x 216 x 292mm WEIGHT approx 14 3 lbs 6 5 kg ACCESSORIES SUPPLIED Instruction Manual Spare fuse OPTIONAL ACCESSORIES Po...

Page 11: ...le supply Read value on V Meter 6 A Meter Indicates output current of variable supply 7 V Meter Indicates output voltage of variable supply 8 OUTPUT Terminal Red Positive polarity output terminal 9 OU...

Page 12: ...CONTROLS AND INDICATORS Figure 1 Front Panel Controls and Indicators Model 1671A Figure 2 Rear Panel Model 1671A 6 14 15 16...

Page 13: ...vent internal heat build up Typically a two inch space at the sides as well as a six inch space at the top and rear of the power supply is adequate DO NOT block the fan opening at the rear of the powe...

Page 14: ...OLTAGE control will not increase the output current Setting Current Limit 1 Determine the maximum safe current for the device to be powered 2 Rotate the VOLTAGE control away from zero until some low v...

Page 15: ...ant as the lad increases up until the point where the preset current limit is reached At that point the output current becomes constant and the output voltage drops in proportion to further increases...

Page 16: ...outputs are fully isolated from ground and each other thus each output may be connected for the either positive or negative polarity A typical example of a triple output application would be powering...

Page 17: ...11 Figure 4 Example of Triple Output Hook up for 5V 12V and 12V Figure 5 Connecting Outputs in Series for Variable 17 to 47 volt output OPERATING INSTRUCTIONS...

Page 18: ...n fuse then replace only with a fuse of the correct rating The fuse is located on the rear panel see Fig 2 LINE VOLTAGE 115V 230V FUSE VALUE F4AL250V F2AL250V INSTRUMENT REPAIR SERVICE Because of the...

Page 19: ...ccount must include payment in the form of a money order or credit card For the most current repair charges please visit www bkprecision com and click on service repair Return all merchandise to B K P...

Page 20: ...n form online at www bkprecision com within fifteen 15 days of purchase Exclusions This warranty does not apply in the event of misuse or abuse of the product or as a result of unauthorized alteration...

Page 21: ...nsformer etc any time the equipment is connected to an ac outlet even if the equipment is turned off 7 B K Precision products are not authorized for use in any application involving direct contact bet...

Page 22: ...B K Precision Corporation 22820 Savi Ranch Parkway Yorba Linda California 92887 www bkprecision com 2016 B K Precision Corporation Printed in China 122116...

Page 23: ...Mouser Electronics Authorized Distributor Click to View Pricing Inventory Delivery Lifecycle Information B K Precision 1671A 1671A NIST W DATA...

Reviews: