48
Under voltage control, you may input s DC voltage through Pin 10 to
control the power supply’s output current value.
1
3
2
4
6
5
7
9
8
10
12
11
13
14
16
15
17
19
18
20
22
21
23
25
24
DC SOURCE
+
-
You may access MENU 6-SPECIAL TEST FUNC
2. EXTERNAL
CONTROL to choose the input voltage range at [EXTERN PROGRAM] to
[10 V / 10 K] for 0 – 10V and [ 5 V / 5 K] for 0 – 5V.
EXTERN VOLT CONTROL= VOLT
EXTERN CURR CONTROL= VOLT
EXTERN PROGRAM= 10 V / 10 K
Current Program – Resistor Mode
This function allows you to program the current output by connecting a
resistance to Pin 10. For this function to be enabled, the output control
must be set to Analog mode. The external resistance range used to control
the full scale of the output voltage can fall into the 0 – 10
kΩ or 0 – 5 kΩ
range. Then access MENU 6-SPECIAL TEST FUNC
2. EXTERNAL
CONTROL to set [EXTERN CURR CONTROL =] to [RES], as shown in
the figure below.
EXTERN VOLT CONTROL= VOLT
EXTERN CURR CONTROL= RES
EXTERN PROGRAM= 10 V / 10 K
Pin 10 and GND Pin 23 can be connected with a resistor to set the power
Summary of Contents for XLN15010
Page 1: ...Model XLN15010 XLN30052 XLN60026 High Power Programmable DC Power Supply USER MANUAL...
Page 20: ...17 voltage is within the specified range...
Page 111: ...108...
Page 113: ...110...