Electric Pressure Fryer
Maintenance
51
9.
Before draining the cleaning solution,
remove the filter bag, screen and pipe connections from the
filter vat. This must be done before draining the cleaning solution.
NEVER
pump water or detergent
through the filter system.
10. Drain the solution into the filter vat and discard.
11. Rinse the pot with hot water, using the pot brush to remove remaining sediment, drain and discard.
12. Close the drain and refill the fryer pot with hot water to the proper level.
13. Add approximately 4 to 6 ounces of distilled (white) vinegar to develop a neutralizing solution. Stir the
solution briefly. Leave in the pot for three to five minutes and discard.
NOTE: Foaming of
shortening after boil-outs is caused by failure to follow proper neutralizing procedures.
14. Repeat steps 11 through 13 as needed to remove all traces of cleaning solution.
15. Rinse the pot again with Cool water, drain and discard.
Damage to the fryer could result if the fryer pot is not completely dry before filling
with shortening. Refill the fryer pot with shortening ONLY when it is completely
dry.
16. Dry the fryer pot, lid, and filter vat
COMPLETELY.
17. Close the main drain and fill with new shortening to the proper level.
Summary of Contents for FKM-TC Series
Page 10: ...Electric Pressure Fryer Introduction 8 Safety Labels ...
Page 11: ...Electric Pressure Fryer Introduction 9 ...
Page 41: ...Electric Pressure Fryer Maintenance 39 Oil Over 250 F Pot Pan No Yes ...
Page 46: ...Electric Pressure Fryer Maintenance 44 Oil Over 250 F Pot Pan No Yes ...
Page 54: ...Electric Pressure Fryer Maintenance 52 18 Confirm the oil level ...
Page 61: ...Electric Pressure Fryer Notes 59 Notes ...