HSS Hot Food Merchandiser
Installation
CS-TM-003.01
Revised 10/01/18
8
Counter Model
Counter mounted units must be mounted on a level surface that can support the weight of the unit and it’s contents. Use a
carpenter’s level to level the unit.
These units are to be sealed to the counter if required by local health codes. Seal the perimeter of the units to the counter
using a silicone-type sealant (Dow Corning RTV #732 or equivalent).
Caster Model
Caster mounted units must be moved to a permanent location and the two swivel casters locked before using.
Do not place heavy objects on top of the unit or damage could occur. The units
are not structurally designed to support excessive external loading.
Wiring
Electrocution, equipment failure or property damage could result if an unlicensed
electrician performs the electrical installation. Ensure that a licensed electrician
perform the electrical installation in accordance with local codes, or in the absence
of local codes, with the National Electrical Code, ANSI NFPA 70-20XX.
This unit, when installed by an authorized BKI service agent, must be wired for use in accordance with all applicable local,
state, and federal codes. For specific electrical requirements and connections refer to the wiring diagram attached to the
unit or provided in the Service Manual.
General Guidelines
•
In the absence of local codes refer to the latest edition of one of the following:
•
National Electrical Code, ANSI/NFPA 70-20XX (USA) which can be obtained from:
The National Fire Protection Association
Batterymarch Park
Quincy, MA 02269
•
I.E.E. Wiring Regulations (Europe)
•
Verify that the power supply conforms to the electrical rating listed on the oven data plate.
•
Ensure that the appliance is grounded (earthed).
Guidelines for European Appliances
Note: -
A method of disconnection from the main supply having a contact separation of least 3mm in all poles must be
incorporated in the fixed wiring.
•
It is recommended that an
R.C.D.
with a 30ma trip and contact rating to suit the appliance current be installed
adjacent to the appliance.
•
Type C/ 3 circuit breakers or appropriate rated fuses are recommended for installation at the supply end.
Note: -
surge currents are present when this appliance is switched on from cold.
•
Industrial plugs and sockets must comply with BS 4343/EN60309 (IEC309.2/CEE17).