Ventless Hood System

 

MODEL FH-28 
Installation & Operation Manual

 

Serial Numbers 123046 and higher

 

 
 

 

 
 

Summary of Contents for Ventless Hood System FH-28

Page 1: ...Ventless Hood System MODEL FH 28 Installation Operation Manual Serial Numbers 123046 and higher ...

Page 2: ...ville South Carolina or F O B authorized BKI Distributor The Company and or its authorized representatives will assume the normal replacement labor expense for the defective part for the period of the warranty as stated above excluding travel and or other expenses incidental to the replacement of the defective part where replacement work is performed during standard business hours and not subject ...

Page 3: ...p 7 Shut Down 8 When to Replace the Filter 8 Cleaning 8 Installation 9 Unpacking and Handling 9 Inspection for Shipping Damage 9 Location and Clearance 9 Leveling 10 Securing 11 Assembly and Mounting 12 Fire Damper 12 Air Deflector 12 Particle Odor Filter 13 Appliance Stop FB37144203 Used with BKI Automatic Lift Fryers 13 Appliance Restraining Device 14 Fire Extinguishing System 15 Wiring 16 Stand...

Page 4: ...low is the safety alert symbol When you see this symbol on your equipment be alert to the potential for personal injury or property damage Safety Signs and Messages The following Safety signs and messages are placed in this manual to provide instructions and identify specific areas where potential hazards exist and special precautions should be taken Know and understand the meaning of these instru...

Page 5: ...igned for this application only other filters will not work properly Use only a BKI particle odor filter Safe Work Practices Beware of High Voltage This equipment uses high voltage Serious injury can occur if you or any untrained or unauthorized person installs services or repairs this equipment Always Use an Authorized Service agent to Service Your Equipment Keep this manual with the Equipment Th...

Page 6: ...t and a fire extinguisher near the equipment You must use a 40 pound Type BC fire extinguisher and keep it within 25 feet of your equipment Keep emergency numbers for doctors ambulance services hospitals and the fire departments near your telephone Know your responsibility as an Employer Make certain your employees know how to operate the equipment Make certain your employees are aware of the safe...

Page 7: ...le Links Fusible links to be UL Listed 165 F load rating 3 45 lbs Pressure Open Fryers Pressure fryers acceptable for use with this hood shall be constructed such that when the lid is released or unlatched it shall spring to the fully open position within four seconds Fully open is defined as vertical upright position 80 or more from the closed position The lid must open without operator or electr...

Page 8: ...ture 375 F 191 C Maximum shortening capacity 110 lbs 50kg Maximum cooking surface area 396 sq in 2555 sq cm USE ELECTRIC FRYERS AND SINGLE VAT FRYERS ONLY Griddles Specifications Volts 208 240 Phase 1 or 3 Maximum Amps 38 5 Maximum Input 8 KW Frequency 60 Hz Maximum griddle surface area 450 sq in 2903 sq cm Maximum cooking surface temperature 450 F 232 C USE ELECTRIC GRIDDLES ONLY ...

Page 9: ...trapped A charcoal filter contained in this particle odor filter helps to remove cooking odors from the air The filtered air then passes through the blower and is returned to the room Preparation The following conditions must be met for the Filter Hood to function The particle odor filter must be installed The grease baffle must be installed The filter door must be shut The fire extinguisher syste...

Page 10: ...n to Replace the Filter The particle odor filter should be replaced when the CHANGE FILTER light illuminates In low to medium volume applications the filter may need replacement prior to the CHANGE FILTER light illuminating If you smell a strong odor coming from the face of the filter and the CHANGE FILTER light is not illuminated the filter needs to be replaced If necessary refer to the procedure...

Page 11: ...inspection of your concealed damage item Packaging material MUST be retained to show the inspector from the shipping line Location and Clearance Place the Filter Hood in a location with clearance as shown in the figure and data below These distances provide for proper clearance to combustible surfaces access for maintenance and proper air flow from hood exit vent MINIMUM CLEARANCE HOOD TO COMBUSTI...

Page 12: ...1 Adjust the four feet provided on the bottom of the unit so there is a minimum of 6 clearance below the frame side members NSF UL REQUIREMENTS 2 Check for level from side to side and front to back using a 4 level placed appropriately on the frame ...

Page 13: ...uired and anchor s if required secure the hood to a wall to prevent movement The outside holes are spaced at 16 inches in the event wall studs can position the unit Brace Mount If the unit is being mounted far away from a wall a brace angle secured to the floor may be bolted to the shelf This brace must be sufficient to prevent movement of the hood Seal brace connection to floor using a food grade...

Page 14: ...st be installed in the damper assembly located at the top of the unit Install as follows 1 Lift the damper 2 Place the link on the damper hook 3 Lower the damper while placing the link onto the stationary hook Air Deflector Mount air deflector as shown in the figure below using two knurled screws provided ...

Page 15: ...y slide the filter into the unit 4 Close and latch the door Appliance Stop FB37144203 Used with BKI Automatic Lift Fryers The Appliance Stop must be installed if a BKI Automatic Lift Fryer with M0084 lift mechanism is to be connected to the hood Failure to install this part could cause damage to the hood and or fryer Install the Appliance Stop FB37144203 on the hood as shown below if a BKI Automat...

Page 16: ...eath could occur if the appliance is not secured to the hood A restraining device has been provided to assure that the cooking appliance remains in the proper position under the hood during normal operation DO NOT REMOVE THE RESTRAINING DEVICE Adjust restraining cable to allow no more than two inches 2 of appliance movement This adjustment must not allow the appliance to go beyond front edge of ho...

Page 17: ...ystem To locate an authorized Range Guard Distributor use the following contact information Ronald Woodward Technical Service Specialist Badger Fire Protection 4251 Seminole Trail Charlottesville Va 22911 Office 800 446 3857 ext 111 Fax 434 974 4113 Mobile 434 981 0505 1 After the hood has been properly secured to prevent movement locate the end of line remote pull station at a point of egress or ...

Page 18: ...inder with adjustable clamping strap 7 Reset control head and connect control to cylinder 8 Recheck installation procedure to insure that nothing has been overlooked Wiring Electrocution equipment failure or property damage could result if an unlicensed electrician performs the electrical installation Ensure that a licensed electrician perform the electrical installation In the event of an applian...

Page 19: ...1 Remove fire extinguisher access panel 2 Route incoming power lines through holes located in the top of the 12 x8 x4 electrical enclosure 3 Connect ground to the lug provided inside the enclosure 4 Perform the applicable step below For single phase operation connect incoming power to terminals L1 and L2 of the contactor For three phase operation connect incoming power to terminals L1 L2 and L3 of...

Page 20: ...Ventless Hood System Installation 18 ...

Page 21: ...d Ground 2 Cover junction box hole with provided plate and hardware removed from receptacle 3 Remove hole plug from hole in bottom of electrical enclosure and install conduit from appliance utilizing appropriate UL Listed fitting not provided 4 Wire appliance as shown in figure below and the electrical diagram in this manual 5 Replace all panels and install cover over hole that was provided for th...

Page 22: ...ning the baffle Weekly User Particle Odor Filter Inspect particle odor filter In low to medium volume applications the filter may need replacement prior to the indicating light turning on This condition will be evident by a strong odor coming from the face of the filter If necessary refer to the procedure in this manual for replacing the filter Monthly User Door and Filter Interlock Check door and...

Page 23: ...unit 2 Open the filter door on the front of the unit by rotating the handle counter clockwise 3 Slide the used filter out of the unit 4 Remove the replacement filter from the plastic bag 5 Observing the UP arrows on the filter with a hand at each front corner carefully slide the filter into the unit When installing a new filter slight resistance should be observed as the filter is being slid into ...

Page 24: ...P O Box 80400 Simpsonville S C 29680 0400 USA http www bkideas com Made and printed in the U S A LI0114 0407 ...