Installation Manual
Fingerprint scanner and code keypad
Installation Manual, edition 3 dated 02/01/2013
Page 22
Copyright © BKS GmbH, 2012. All rights reserved.
C 59 501 107
GENERAL ADVICE
These instructions are intended for trained electricians or specialists in security in-
stallations.
The appropriate local installation specifications, directives and regulations must be
followed. This particularly applies for VDE directives and regulations, e.g. German
directive for electrical locking systems in doors in escape routes (EltVTR), DIN VDE
0100, DIN VDE 0160, DIN VDE 0185, DIN VDE 0632.
A primary side circuit breaker for the power supply circuit of the power supply units
and a suitable protective device (fuse) must be provided on site.
The mains power input and the outgoing power supply cable to the power supply
units must be routed separately without fail. When routing the cables, avoid sharp
edges and tension in the cables.
For the operating and installation instructions and maximum permissible output cur-
rent of the power supply units, refer to the enclosed data sheets.
With central power supply units that supply several doors, a separate supply cable
must be provided for each door. The maximum distance between the door and
power supply unit must not exceed 50 m.
Before starting any installation, repair, service or adjustment work, ensure that no
voltage is applied to any of the mains adapters to avoid unintended switch-on.
In case of any damage, caused by not following the instructions, warranty automati-
cally expires. BKS is not liable for any damage caused by not following the instruc-
tions.
With regard to safety and to product approval (CE), it is not permitted to change or
alter the product in any manner without our authorisation.