Installation Manual
Fingerprint scanner and code keypad
2.5 Cable routing of module
Please use the enclosed system cable to connect the module. The SECUREconnect and the
access control module communicate via an encoded bus.
Connecting cable
Signal
GND (minus)
Grey (blue)
Brown
24 V (plus)
Black Control
line
Connecting cable
Signal
Yellow GND
(minus)
White RS-485
A
Green RS-485
B
Brown
24 V (plus)
2.6 Pairing
In the version with inbuilt profile the SECUREconnect and access control module are paired
automatically. If the hardware is replaced, both components (SECUREconnect and ZUKO
module) must be replaced as the pairing cannot be terminated.
Installation Manual, edition 3 dated 02/01/2013
Page 29
Copyright © BKS GmbH, 2012. All rights reserved.
C 59 501 107