EN
4
5
6.
Charging current for batteries: from 30Ah to 80Ah.
Maintenance mode for batteries: from 30Ah to 120Ah.
Suitable for charging WET or GEL batteries.
7.
Mode for charging AGM-START&STOP and AGM-SPIRAL batteries.
8.
Charge LED indicator (orange).
9.
Full LED: lightening up green when fully charged.
10.
Reverse polarity LED (red).
11.
Fault LED: lightening up when there is an issue with the battery (red).
12.
Output lead: Cable with clamps 30A - Ref: BXAE00025.
13.
Output lead: Cable with rings 6mm and protective, insulating, watertight cap.
2.1.
Technical specifications
Reference
BXAE00022
Model
Charger 6/12V-4A
Voltage (Mains)
220~240V AC 50/60Hz
Charging voltage
6V / 12V
Charging current
1A / 4A
Battery size
4Ah to 120Ah batteries
Operating temperature
-10° to +40°C
Storage temperature
-20° to +50°C
IP indication
IP65
Minimum battery voltage
0,8V
2.2.
Battery types
This electronic battery charger is designed to charge all types of lead batteries,
conventional batteries and batteries of the latest generation. This battery charger is ideal
for both everyday use, as a key working tool, and extensive charging cycles. All charging
parameters are set using the charge function key on the control panel.
2.3.
Charge cycles
The charge cycles of the battery charger have been specially developed to optimize the
charge of all types of batteries currently available in the market. The numerous
constructional technologies of currently available batteries require different charging
curves to ensure correct and complete charging. This battery charger extends the lives of
your batteries because it provides each with the proper charge cycle.
2.4.
Interruption of the charge cycle
In case of blackouts in the 230V mains, the battery charger saves the work cycle it was
performing in order to restore it automatically as soon as the power supply of the 230V
mains is restored. This function is crucially important if the battery charger is used to
charge batteries without the operator supervising the cycle; for example, during very long
work cycles (maintenance charges) or when charging overnight (charges for vehicles that
need to be charged daily). The set parameters are stored for 12 hours; after 12 hours the
battery charger will resume charging with the default parameters.
2.5.
Safety devices