background image

7

ENGLISH

(Original instructions)

This occurs when the unit is not operating.

To wake up the system, the user will need to push the

pressure mode / reset button (5) . At this time the LCD will

turn on and the inflator is ready for use.

u

  Before switching your inflator on decided which power

  source you will be using; 12V DC adapter, 230V AC plug

  or a 20V MAX* battery pack.

u

  To use the 12V DC adapter, or 20V MAX* battery pack

  press the AC/DC power switch (1) located on the front of

  the unit to DC.

u

  If using the 12V DC cord, ,always fully extend the 12V DC

  cord before each use.

 

u

  Connect the 12V DC adapter 14 into your vehicles

    12V DC accessory socket.

To use the 230V AC cord, press the AC/DC switch 1 located

on the front of the unit to AC.

u

  If using the 230V AC cord 13 , always fully extend the

  cord before each use.

 

u

  Connect the 230V AC plug 13 into either a wall

    outlet or an approapriate sized extension cord that

    is plugged into a wall outlet.

To turn on high-volume

The high-volume hose is meant to be used for objects that

hold large amounts of air, such as air mattresses, rafts, and

swimming pool floats.

Note:

 The high-volume mode DOES NOT have an auto

shut-off feature.

u

  Attach the high-volume hose (7) to the high volume pump 

inflator connection (12) as described in the “High

  volume hose” section.

u

  Insert the high-volume hose (7) , or it’s tapered nozzle (8)

  into the object being inflated.

u

  Press the high-volume side of the mode power switch (2) , 

indicated by the air mattress symbol.

u

  To turn off, push the power switch to the center position.

To turn on high-pressure

The high-pressure hose is meant to be used for objects that

need more air pressure, such as tires and basketballs.

u

  Remove the high-pressure hose (10) from the storage.

u

  Attach a nozzle as described in the “Universal valve

  adapter” section.

u

  Insert the nozzle into the object being inflated.

u

  Press the high-pressure side of the mode power switch 

(2), indicated by the tire symbol.

u

  To turn off, push the power switch to the center position.

Deflate using the high-volume hose (Fig. H)

Warning!

 Beware of objects being ejected. When deflating, 

large amounts of air will exit the high volume pump inflator 

connection (12) . Ensure the universal valve adapter is not 

pointed at anyone or anything.

u

  Remove the high-volume hose (7) from the storage 

location.

u

  Line up the hose end (23) with the high-volume pump

  deflate connection (11) . Then, firmly slide in the hose so it

  is securly in place.

u

  Insert the hose, or it’s tapered nozzle (8) into the object

  being deflated.

u

  Press the high-volume side of the mode power switch (2), 

as shown in figure G, indicated by the air mattress symbol.

u

  To turn off, push the power switch to the center position.

u

  To remove the hose, twist the hose clockwise and slide

  hose off.

Setting the automatic shut-off pressure

Note:

 The LCD will only show inflation pressures when the

inflator is being used. In both inflation and pump mode the

unit will show battery status.

u

  To switch between the different units (psi, bar or kPa),

  press the pressure mode button (5) until the required

  units are displayed.

u

  Press the - or + pressure setting buttons (4) until the

  required pressure is displayed.

u

  After 3 seconds the display will flash and return to a

  reading of “0.0”. This is normal.

u

  Connect the universal valve adaptor and accessories,

  if required, to the item to be inflated, making sure that

  the lever of the valve adaptor is in the down position to

  lock it in place.

u

  To start the inflator press the mode power switch (2) ,

  towards the side of the tire symbol.

u

  When the item to be inflated has reached the preset

  value the unit will automatically turn off. NOTE: You

  may notice the actual pressure reading may drop after a

  couple of seconds. This is normal.

u

  To stop the inflator at any time, press the main power

  button back to the center position.

Note:

 If the AC/DC power switch is turned off, all settings

will be lost and will need to be reentered. This is a safety

feature to prevent the risk of items over inflating.

Using the inflator as a pressure gauge

u

  Connect the universal valve adaptor (9) to the item to be 

checked.

u

  Press the mode power switch (2) , on the side of the tyre

  symbol.

u

  The LCD will display the item’s pressure.

u

  After checking, press the mode power switch (2) back to 

the center position and return the air hose to the storage 

location.

Summary of Contents for BDCINF18

Page 1: ...www blackanddecker eu BDCINF18 1 12 17 18 5 2 9 11 14 13 10 7 3 6 15 16 8 4 ...

Page 2: ...2 15 16 17 18 19 22 21 20 12 7 A B C D 1 E 2 F ...

Page 3: ... Retain this manual for future reference u This appliance is only to be used with the battery packs listed in the manual as cordless power u If the supply cord is damaged it must be replaced by the manufacturer its service agent or similarly qualified persons in order to avoid a hazard Using your appliance u Do not use the appliance to pick up liquids or any materials that could catch fire u Do no...

Page 4: ... Use a tire gauge to check the tyres pressure before each use and while inflating tyres see the tyre sidewall for the correct tyre pressure u Do not modify or attempt to repair Never drill into weld or make any modifications to the inflator or its attachments u Operate only with the accessories in cluded or air handling parts acceptable for not less than 160 psi u The use of any accessory not reco...

Page 5: ...r only to charge the battery in the tool with which it was supplied Other batteries could burst causing personal injury and damage u Never attempt to charge non rechargeable batteries u Have defective cords replaced immediately u Do not expose the charger to water u Do not open the charger u Do not probe the charger Electrical safety Symbols on the charger Read all of this manual carefully before ...

Page 6: ... pump inflator connection 12 Then slide the hose on and twist counter clockwise to secure u To remove twist the hose clockwise and slide hose off Note Many inflatables have an internal flap that prevents air loss during inflation especially air mattresses Unless this flap is displaced by the nozzle the inflatable will not inflate Push the nozzle firmly into the valve to make sure that you push thi...

Page 7: ... of objects being ejected When deflating large amounts of air will exit the high volume pump inflator connection 12 Ensure the universal valve adapter is not pointed at anyone or anything u Remove the high volume hose 7 from the storage location u Line up the hose end 23 with the high volume pump deflate connection 11 Then firmly slide in the hose so it is securly in place u Insert the hose or it ...

Page 8: ...Battery Class ll Battery BL1318 Voltage Vdc 18 Capacity Ah 1 3 Type Li lon Battery BL1518 Voltage Vdc 18 Capacity Ah 1 5 Type Li lon Battery BL2018 Voltage Vdc 18 Capacity Ah 2 0 Type Li lon Battery BL4018 Voltage Vdc 18 Capacity Ah 4 0 Type Li lon Battery BL1554 Voltage Vdc 18 Capacity mAh 2500 Type Li lon Battery BL2554 Voltage Vdc 18 Capacity mAh 2500 Type Li lon Alternative Bluetooth Battery p...

Reviews: