27
Common Power Output Problems
Possible Causes
Recommendations
Battery voltage below 10.5 volts
Recharge battery or check DC power supply.
Equipment being operated draws too much power
Reduce load to maximum 200 watts.
Inverter in thermal shutdown condition
Allow inverter to cool down. Ensure there is adequate
ventilation around the unit, and the load is no more
than 200 watts for continuous operation.
AC output is shorted
Unplug the AC appliance. Disconnect the unit from
any 12 volt DC power source, then reconnect the unit
BEFORE plugging the appliance back in.
SERVICE INFORMATION
Black & Decker offers a full network of company-owned and authorized service locations. All
Black & Decker Service Centers are staffed with trained personnel to provide customers with
efficient and reliable power tool service. Whether you need technical advice, repair, or genuine
factory replacement parts, contact the Black & Decker location nearest you.
SPECIFICATIONS
Maximum Continuous Power:
200 Watts
Surge Capacity:
400 Watts
USB Output:
5 V DC (500mA)
Input Voltage:
12.8 volts
Low Voltage Alarm:
11.0 ± 0.3 volts DC
Low Voltage Shutdown:
10.5 ± 0.3 volts DC
Thermal Shutdown:
Automatic
Wave Form:
Modified Sine Wave (MSW)
Fuses: Internal:
25 Amps/DC Accessory Plug: 8 Amps
Input Cables:
Battery clip cables and 12V Accessory Plug
Operating Temperature:
10-20°C (50-68°F)
Storage Temperature:
0-40°C (32-104°F)
Operating/Relative Humidity:
5-95% non-condensing