background image

7

Battery Replacement/Disposal

It is recommended that the unit be returned to Customer Service
for battery replacement. Contact toll-free (800) 618-5178.
This unit contains a maintenance-free, non-spillable, sealed lead-
acid battery. This battery is fully recyclable and should be
accepted at any location that accepts common automotive
starter batteries. Examples of places that accept these batteries
are: county or municipal recycling drop-off centers, scrap metal
dealers and retailers who sell automotive replacement lead acid
starter batteries. 

WARNINGS

Do not dispose of the battery in fire, as this may result in an explosion.
Before disposing of the battery, protect exposed terminals with
heavy-duty electrical tape to prevent shorting (shorting can result in
injury or fire).
Do not expose battery to fire or intense heat, as it may explode.

Fuse Replacement (DC Accessory Adapter)

1. Remove plug from accessory receptacle. Remove the gold cap by turning

counterclockwise and lifting off. 

2. Remove center pin and spring. Remove fuse.
3. Replace fuse with same type and size fuse. 
4. Replace center pin and spring inside plug.
5. Replace gold cap by turning clockwise.

SPECIFICATIONS

Jump-Start Clamps:

Heavy-duty copper

Jumper Cables:

#6AWG welding cables

Instant Starting Amps:

300 amps

AC Power Output: 

250 watts AC

DC Power Output:

12 volts DC

Battery High-density 

AGM:

12 volt, 9 amp hour, sealed lead-acid

Accessory Outlet 

Protection:

Automatic overload protection

6

4. AC Power Ground Fault Circuit Interrupt (GFCI) — A 3-prong outlet for 120 volt

AC appliances which shuts down inverter if leakage or ground fault current is
detected.

5. Internal protective circuits including:

• Overload and over-temperature shutdown (activated if AC output exceeds

250 watts)

• AC short-circuit shutdown
• Low voltage shutdown
• A new cooling technology that more efficiently cools the power transistors and,

combined with soft start, dramatically increases reliability and product life

AC Power Supply Controls and Indicators

The Inverter ON/OFF Switch turns the AC power circuitry on and off. The ON/OFF
switch can also be used to reset the AC power after shutdown due to overvoltage,
overload or over-temperature condition. The AC outlet (covered when not in use)
supplies power to AC appliances.

AC Power Supply Operation

1. Turn power switch to ON (the power indicator lights).
2. Plug in appliance and turn the appliance on.

Note:

The AC power supply shuts down automatically when the battery voltage level
is too low. If the LED flashes, a faulty condition such as an overload,
overheating or short circuiting has occurred. Turn the AC Power Supply off and
unplug the appliance. Wait a few minutes, then turn power back on.

USING THE EMERGENCY AREA LIGHT

The Area Light is controlled by the ON/OFF slide switch directly above it on the front
panel. Make sure the light is turned OFF when the unit is being recharged or stored. 

CARE AND MAINTENANCE

CAUTION

If the cord, wires, or cables become damaged, do not attempt to use.
Return the entire unit to Vector Manufacturing for service and repair.

Replacement Parts

For replacement parts (bulbs, batteries, fuses, etc.), contact Customer Service toll-free
at (800) 618-5178.

VEC1026BD_Manual_050305  5/9/05  2:25 PM  Page 6

Summary of Contents for ElectroMate 250

Page 1: ...able design The repaired or replaced unit will then be warranted under the terms of the remainder of the warranty period The customer is responsible for the shipping charges on all returned items after 30 days During the warranty period manufacturer will be responsible for the return shipping charges LIMITATIONS This warranty does not cover accessories bulbs fuses and batteries defects resulting f...

Page 2: ...posed terminals with heavy duty electrical tape to prevent shorting shorting can result in injury or fire 13 Do not smoke or use flammable items matches cigarette lighters etc while working on a vehicle s battery system 14 Whether stored or in use keep this unit out of reach of children 15 Do not operate charger in rain or snow nor use when wet 16 DO NOT ATTEMPT TO JUMP START A FROZEN BATTERY 17 W...

Page 3: ...his guide carefully before use to ensure optimum performance and avoid damage to the unit FEATURES Powers 110 120 volt AC appliances Powers 12 volt DC appliances Jump starts vehicle engines Built in 250 watt inverter Includes non spillable maintenance free heavy duty sealed battery Safe to use transport and store Alternator check Reverse polarity connection warning Detachable jumper cables Require...

Page 4: ...ging from 120 volt AC The 12 volt DC recharging procedure is recommended only when it is necessary since frequent use of the 12 volt DC recharging procedure may shorten the battery system s life 1 Insert the gold tipped DC DC charging adapter plug into the vehicle s 12 volt DC accessory outlet 2 Insert the silver tipped end plug into the 12 volt DC accessory outlet on the front panel of the unit 3...

Page 5: ...system to jump start any vehicle read and understand all instructions safety tips warnings cautions and first aid information provided in this manual and on the product labeling Additional important information may also be provided in the battery manual CAUTION To avoid possible damage that may shorten the unit s working life protect this unit from direct sunlight direct heat and moisture This sys...

Page 6: ... 3 prong outlet for 120 volt AC appliances which shuts down inverter if leakage or ground fault current is detected 5 Internal protective circuits including Overload and over temperature shutdown activated if AC output exceeds 250 watts AC short circuit shutdown Low voltage shutdown A new cooling technology that more efficiently cools the power transistors and combined with soft start dramatically...

Reviews: