TROUBLESHOOTING GUIDE
Common Power Output Problems – 115 Volt AC
Possible Cause
Recommendations
Red battery status LED indicator is
Unit is in charging mode. For optimum
flashing and there is no output
results, allow unit to complete charging
cycle before using.
Battery Status LED indicators are
Charging is complete, disconnect
all lit, but there is no output
charging adapter from unit and wall
receptacle. Wait 5 minutes before using
inverter.
Inverter sudden shutdown,
Overload condition, reduce load to a
Inverter Status LED is lit red
maximum of 80 watts and attempt a
and green Battery Status LEDs are lit
manual reset
Inverter Status LED is lit red
Unit shutdown from overload or
and green Battery Status LEDs are lit,
fault condition, attempt manual
but there is no AC power
reset and reduce load
LED indicators are off,
Hold ON/OFF pushbutton for at
unit may not be in the ON position
least 1 second to turn unit ON
Unit shuts down after a few
Internal battery pack needs
minutes, internal battery voltage
recharging, refer to charging
is low
instructions on page 7
Common Power Output Problems – USB Outlets
Possible Cause
Recommendations
No power from USB port
Hold ON/OFF Pushbutton for at least 1
second to turn unit on.
Device connected to USB port
Be sure device can be charged through
is not charging
USB Port and current draw is not larger
than 500 mA
For assistance with your product, visit our website www.blackanddecker.com for
the location of the service center nearest you or call the BLACK & DECKER help
line at 1-800-544-6986.
10