background image

VEHICLE POWER SYSTEM

POWER INVERTER

200/400/750 WATT 

VEC1045BD / VEC1046BD / VEC1047BD

USER’S MANUAL 

& WARRANTY INFORMATION

IIIIM

M

M

MPPPPO

O

O

ORRRRTTTTA

A

A

AN

N

N

NTTTT SSSSA

A

A

AFFFFEEEETTTTYY

Y

Y IIIIN

N

N

NFFFFO

O

O

ORRRRM

M

M

MA

A

A

ATTTTIIIIO

O

O

ON

N

N

N,,,, SSSSA

A

A

AV

V

V

VEEEE TTTTHHHHEEEESSSSEEEE IIIIN

N

N

NSSSSTTTTRRRRUUUUC

C

C

CTTTTIIIIO

O

O

ON

N

N

NSSSS

TO REDUCE THE RISK OF INJURY, USER MUST READ AND UNDERSTAND
THIS INSTRUCTIONAL MANUAL. THIS MANUAL CONTAINS IMPORTANT
INFORMATION REGARDING THE OPERATION AND WARRANTY OF THIS
PRODUCT. PLEASE RETAIN FOR FUTURE REFERENCE.

www.vectormfg.com

4140 S.W. 30th Ave., Ft. Lauderdale, FL 33312

Toll Free: (800) 618-5178

8

Fault Protection Code and Troubleshooting Guide

INVERTER POWER SWITCH TURNED ON

SPECIFICATIONS

Power Inverter Model

VEC1045BD

VEC1046BD

VEC1047BD

Maximum Continuous Power: 

200 watts

400 watts

750 watts

Surge Capacity: 

400 watts

800 watts

1500 watts

Input Voltage:

12.8 volts

Output Voltage: 

Approx. 115 volt AC RMS 60 Hz

Low Voltage Alarm:

11 volts DC ± 0.3 volt DC

Low Voltage Shutdown:

10.5 volts DC ± 0.3 volt DC

Thermal Shutdown:

Automatic

Wave Form:

Modified Sine Wave (MSW)

Output Connection:

North American Standard Receptacles

Input Fuses: 

Internal

Input Cables:

Battery cable with ring connector

Additional Protection:

Overload, over voltage, overheating

Trouble/Indication 

Possible Cause 

Suggested Remedy

No AC output —

DC input is out of range

Check battery voltage. 

(red LED lit

Excessive load —

Turn unit off. Reduce the load,

thermal shutdown

wait for the inverter to cool 
down, then turn the unit on
again.

No AC output —

Fuse(s) open

Check DC input — fuse(s) in

green LED not lit

vehicle. Replace the fuse with 
one of the same type and rating
if necessary. 

Low battery alarm

Low battery voltage

Recharge battery. Remove 

sounds continuously

load from the inverter while
recharging battery.

Bad connection or wiring

Tighten all DC connections.

Motorized power tool

Excessive start-up load

If appliance does not start, 

will not start

appliance is drawing  
excessive voltage and
will not work with inverter.

Motorized power tool

Purely inductive load

Make the load not purely 

does not operate at 

inductive. Operate an 

correct speed

incandescent lamp at the
same time as motor.

Television/Radio

Snow in picture, 

Keep inverter and antenna

interference

“buzzing” sound

distant from each other. Use
shielded antenna. Connect
antenna to amplifier.

VEC1045_46_47_BD_Manual  4/28/05  5:16 PM  Page 8

Summary of Contents for VEC1045BD

Page 1: ... Thermal Shutdown Automatic Wave Form Modified Sine Wave MSW Output Connection North American Standard Receptacles Input Fuses Internal Input Cables Battery cable with ring connector Additional Protection Overload over voltage overheating Trouble Indication Possible Cause Suggested Remedy No AC output DC input is out of range Check battery voltage red LED lit Excessive load Turn unit off Reduce th...

Page 2: ... strips with switches and circuit breakers only interrupt power to the hot receptacle terminals The neutral terminals remain powered with respect to the ground terminals NOT approved for ignition protected areas Do not make any electrical connections or disconnections in areas designated as IGNITION PROTECTED This is not a toy keep away from children This equipment employs components that tend to ...

Page 3: ...other than accessories may be returned postage prepaid to manufacturer Any defective product other than accessories that is returned to manufacturer within 30 days of the date of purchase will be replaced free of charge If such a product is returned more than 30 days but less than two years from the purchase date manufacturer will repair the unit or at its option replace it free of charge If the u...

Page 4: ...VE and the side contact is NEGATIVE Connect the inverter to the power source by inserting the DC accessory outlet plug firmly into the accessory outlet of a vehicle or other DC power source CAUTIONS Connect directly to power source when operating above 100 watts Do not use with positive ground electrical systems Reverse polarity connection will result in a blown fuse and may cause permanent damage...

Page 5: ...nal of the DC power source battery 8 Insert a fuse appropriate to the inverter in the fuse holder 4 Notes Most vehicle accessory outlet circuits have fuses rated at 15 to 20 amps or greater To operate at full wattage either use the battery clip cable supplied or directly wire to the power source with user supplied wire and fuse The majority of modern automobiles RVs and trucks are negative ground ...

Page 6: ...N Loose connectors may cause overheated wires and melted insulation Check to make sure you have not reversed the polarity Damage due to reversed polarity is not covered by our warranty Connection To Load The Power Inverter is equipped with dual standard North American AC power receptacles Plug the cord from the equipment you wish to operate into the AC receptacle s Make sure the combined load requ...