4. DIP Switches

Table 4-1 describes the DIP Switches. Select the switches for optimal configuration.

Table 4-1. DIP switches and their functions.

Table 4-2. DIP switches’ descriptions.

Figure 4-1. DIP switches’ default settings.

DIP Switches

SW-1

SW-2

SW-3

SW-4

Definition

Master/Slave

Impulse Noise  
Protection Mode

Data Rate

SNR

Off

Master

Interleaved

50/20 Mbps

9 dB

On

Slave

Fast

Full Rate

6 dB

Standard extender

PD extender

SW-1: CO/Remote 

 

Off: VDSL2 PoE Ethernet Extender will act as the master side. 

 

On: VDSL2 PoE Ethernet Extender will act as the slave side. 

SW-2: Mode for impulse noise protection 

 

Off:  Interleaved mode provides impulse noise protection for any impulse noise with a duration less than 250 µs. 

Interleaved mode has a maximum end-to-end latency of 10 ms. Interleaved mode is the default mode. 

 

On: Fast mode guarantees a minimum end-to-end latency less than 1 ms. 

SW-3: Rate limit control 

 

Off: Line rate limited to 50/20 Mbps. 

 

On: Provides up to 100-/60-Mbps line rate at distances up to 500 feet (152.4 m).

SW-4: Signal-to-noise ratio (SNR) 

 

Off: Higher SNR margin (9 dB) will result in fewer errors with a more stable VDSL link. 

 

On: Original and normal channel noise protection with 6 dB SNR.

VDSL2 PoE Ethernet Extender Kit, PD

Summary of Contents for LBPD01A-KIT

Page 1: ...t and Interleaved modes Provides low latency for video voice data applications IEEE 802 3af PoE compliant VDSL2 PoE Ethernet Extender Kit PD Order toll free in the U S Call 877 877 BBOX outside U S call 724 746 5500 FREE technical support 24 hours a day 7 days a week Call 724 746 5500 or fax 724 746 0746 Mailing address Black Box Corporation 1000 Park Drive Lawrence PA 15055 1018 Web site www blac...

Page 2: ...h Support at 724 746 5500 or go to blackbox com and click on Talk to Black Box You ll be live with one of our technical experts in less than 20 seconds Trademarks Used in this Manual Black Box and the Double Diamond logo are registered trademarks of BB Technologies Inc Any other trademarks mentioned in this manual are acknowledged to be the property of the trademark owners ...

Page 3: ...ent is operated in a commercial environment Operation of this equipment in a residential area is likely to cause interference in which case the user at his own expense will be required to take whatever measures may be necessary to correct the interference Changes or modifications not expressly approved by the party responsible for compliance could void the user s authority to operate the equipment...

Page 4: ...es que impidan el flujo de aire por los orificios de ventilación 10 El equipo eléctrico deber ser situado fuera del alcance de fuentes de calor como radiadores registros de calor estufas u otros aparatos incluyendo amplificadores que producen calor 11 El aparato eléctrico deberá ser connectado a una fuente de poder sólo del tipo descrito en el instructivo de operación o como se indique en el apara...

Page 5: ...tested and found to comply with the protection requirements of European Emission Standard EN55022 EN61000 3 and the Generic European Immunity Standard EN55024 EMC EN55022 2003 CISPR 2 2002 Class A IEC61000 4 2 2001 4 KV CD 8 KV AD IEC61000 4 3 2002 3 V m IEC61000 4 4 2001 1 KV power line 0 5 KV signal line ...

Page 6: ... 6 1 Specifications 7 2 Overview 8 2 1 Introduction 8 2 2 Features 8 2 3 Application 8 2 4 What s Included 9 2 5 LED Descriptions 9 2 6 Front and Back Panels 10 3 Installation 11 4 DIP Switches 12 VDSL2 PoE Ethernet Extender Kit PD ...

Page 7: ...3u Ethernet 10BASE 100BASE TX IEEE 802 3af PoE PoE Power Reception Supports Endpoint Via twisted pair Pins 1 2 3 6 Midspan Via twisted pair Pins 4 5 7 8 Connectors PD 1 RJ 11 1 RJ 45 Standard 1 RJ 11 2 RJ 45 Indicators PD 4 LEDs Power LAN DSL M S Standard 5 LEDs Power LAN1 LAN2 DSL M S Power Input PD 100mA 48 VDC from IEEE 802 3af PSE or PoE injector Standard 5 VDC 1 amp Temperature Tolerance Oper...

Page 8: ...h as a PoE Ethernet Switch so it may work without an external power adapter Installation is plug and play You can configure each LBPD01A KIT as either master for central side CO or slave for remote side RT by using the DIP switch settings The LBPD01A KIT conforms to the ITU T G 993 1 and G 993 2 to meet VDSL VDSL2 and SG15Q4 DMT for network requirements 2 2 Features ITU T G 993 1 G 993 2 VDSL VDSL...

Page 9: ...hernet Extender Standard 1 5 VDC 1 A power adapter for VDSL2 PoE Ethernet Extender Standard This user s manual on CD ROM 2 5 LED Descriptions LED Color Function POWER Green Lights when power is on DSL Green Lights when VDSL is connected M S Green Lights when the device is in slave mode Off when device is in master mode LAN Green Lights when Ethernet connection is made Blinks when transmitting rece...

Page 10: ...r PD PD unit Figure 2 4 Front panel VDSL2 PoE Ethernet Extender PD Standard unit Figure 2 3 Rear panel VDSL2 PoE Ethernet Extender PD PD unit Figure 2 5 Rear panel VDSL2 PoE Ethernet Extender PD Standard unit RJ 11 Connector RJ 45 Connector LED Indicators DIP Switches LED Indicators DIP Switches RJ 11 Connector Power Input RJ 45 Connectors VDSL2 PoE Ethernet Extender Kit PD ...

Page 11: ...PD will not work 3 Connect the power adapter to the Standard extender and plug it in NOTE The interconnecting cables should be rated for external use and appropriate for the application s voltage current anticipated temperature flammability and mechanical serviceability Table 3 1 shows the data rate and transmission distance information via 26 AWG at 6 dB Table 3 1 Supported data rates and transmi...

Page 12: ...side On VDSL2 PoE Ethernet Extender will act as the slave side SW 2 Mode for impulse noise protection Off Interleaved mode provides impulse noise protection for any impulse noise with a duration less than 250 µs Interleaved mode has a maximum end to end latency of 10 ms Interleaved mode is the default mode On Fast mode guarantees a minimum end to end latency less than 1 ms SW 3 Rate limit control ...

Page 13: ...ng from cabinets and racks and power and surge protection products to media converters and Ethernet switches all supported by free live 24 7 Tech support available in 20 seconds or less Copyright 2009 All rights reserved Black Box Tech Support FREE Live 24 7 Tech support the way it should be Great tech support is just 20 seconds away at 724 746 5500 or blackbox com ...

Reviews: