18
16-PORT TYPE 3 MAU
3. Installation
3.1 Installation Background
This section gives general information on planning the network using MAUs,
and later sections will cover the installation of the MAU.
Before installing your MAUs and attaching devices, it is very important that
the network be carefully planned. The most important factors for the physical
part of the network are:
• Main ring length and distance between MAUs
• Length of the lobes attaching MAUs to devices
• Number of wiring closets
• Verifying that the proper type of cable is used (see
Section 1.3, Cable
Specifications
)
• Safeguarding against electrical interference, especially when Type 3 cable
is used.
A copy of the floor plans of the buildings that will use the token-ring
network will help greatly in planning the installation.
NOTE
When using Type 3 cable with 4-Mbps token rings, Black Box
®
Media
Filters (part number LT057) must be used to take full advantage of the
lobe lengths stated in this chapter. When using Type 3 cable at 16Mb,
Media Filters must be used. Using another brand of media filter may
result in decreased lobe length.