27
16-PORT TYPE 3 MAU
Completing the Installation
Once the network has been thoroughly planned and all wiring has been
routed to the work areas where network devices will be located, follow the
procedure given in
Section 3.4, Completing the Installation
.
3.3 Distance Charts
The charts on the following pages are used with the distance formula given in
Section 3.2, Calculating Distances
.
Table 3-1. 4-Mbps Distance Chart for Type 3 Cable. Distances are
given in feet (meters).
Number
Number of Wiring Closets
of MAUs
1
2
3
4
5
19 Gauge
1
600 (183)
2
585 (181)
575 (175)
3
570 (174)
560 (171)
550 (168)
4
555 (169)
545 (166)
535 (163)
525 (160)
5
540 (165)
530 (162)
520 (158)
510 (155)
500 (152)
6
525 (160)
515 (157)
505 (154)
495 (151)
485 (148)
7
510 (155)
500 (152)
490 (149)
480 (146)
470 (143)
8
495 (151)
485 (148)
475 (145)
465 (142)
455 (139)