Thank you for purchasing an LWS300A Wireless Serial Server!

 Like all 

Black Box products, your serial server has been manufactured to high 
standards of quality and performance to ensure your complete satisfaction. 
Please read this manual and carefully follow the instructions to achieve best 
results. For additional information on this and other products, and for 
technical support, call 724-746-5500, or access the Black Box website at: 
www.blackbox.com 

About Your LWS300A Wireless Serial 
Server 

LWS300A Wireless Serial Servers

 are part of Black Box growing family of 

device servers, products that allow you to connect equipment with available 
serial connections into existing networks. LWS300A wireless serial servers 
connect RS-232, RS-422 or RS-485 devices to a wireless network via 
wireless access points, eliminating the need for network cabling. Based on 
the 802.11b wireless standard, LWS300A servers operate at up to 11 Mbps 
over the 2.4 GHz band, which does not require licensing.  

LWS300A wireless serial servers are built for use in industrial environments 
and feature rugged DIN or panel mountable enclosures. They feature a wide 
DC power supply range and removable screw terminal power connectors. 

A serial device connected to the serial port on your LWS300A can be 
accessed from any node on the LAN using 

virtual COM port, console 

management, TCP and UDP socket, serial bridge, terminal, modem 
emulation

 and 

custom connections

. Network addresses can be obtained 

dynamically or manually. Simple Network Management Protocol (SNMP) is 
supported. Configuration is accomplished through a web-based user 
interface. 

Introduction

 

Manual Documentation Number: LWS300A-1105m pn7008-rev000 

Chapter 1 

Black Box Corporation - 1000 Park Drive - Lawrence, PA 15055-1018 

www.blackbox.com 

-- Tech Support and Ordering: 724-746-5500 - Fax: 724-746-0746 

 

Features 

 

Wireless networking at up to 11 Mbps on the 2.4 GHz band, as specified 
by the 802.11b standard 

 

Multi-interface switch-selectable serial port supports RS-232, RS-422 
and RS-485 using a standard DB-M connector 

 

Supports TD, RD, TRS, CTS, DTR, DCD, DSR and GND RS-232 lines 

 

LAN and WAN Communications via wireless access point 

 

TCP or UDP Client or Server operation - configurable 

 

Software Support - Windows 98/ME/2000/XP or NT 4.0 

 

Firmware Upload for future revisions/upgrades 

 

Rugged DIN rail or panel mountable IP30 enclosure 

 

LEDs indicate link integrity and data transfer activity 

 

10/100 Mbps auto-detecting operation 

 

Web Configuration and Management user interface 

 

Email event notification 

Communication Modes 

LWS300A Wireless Serial Servers 

allow you to connect serial devices over 

a wireless network. The connection can be configured in several modes. 

Direct IP 

Direct IP Mode

 allows applications using TCP/IP or UDP/IP socket 

programs to communicate with the asynchronous serial ports on the serial 
server. In this mode the LWS300A is configured as a TCP or UDP server. 
The socket program running on the PC establishes a communication 
connection. The data is sent directly to and from the serial port on the server.  

 

TCP Server Mode 

allows network devices to initiate a TCP connection 

to the serial device connected to the serial port on the LWS300A. This is 
also referred to as reverse telnet. 

 

UDP Server Mode 

allows network devices to initiate a UDP connection 

to the serial device attached to the serial port of the LWS300A. When 
using UDP protocol the LWS300A can be configured to broadcast data 
to and receive data from multiple IP addresses.  

Summary of Contents for LWS300A

Page 1: ...port and Ordering 724 746 5500 Fax 724 746 0746 8 80 02 2 1 11 1b b W Wi ir re el le es ss s S Se er ri ia al l S Se er rv ve er r M Mo od de el l L LW WS S3 30 00 0A A Manual Documentation Number LWS300A 1105m Black Box Corporation 1000 Park Drive Lawrence PA 15055 1018 www blackbox com Tech Support and Ordering 724 746 5500 Fax 724 746 0746 ...

Page 2: ...anual Documentation Number LWS300A 1105m Table of Contents Black Box Corporation 1000 Park Drive Lawrence PA 15055 1018 www blackbox com Tech Support and Ordering 724 746 5500 Fax 724 746 0746 CHAPTER 5 USING THE WEB CONFIGURATION AND MANAGEMENT INTERFACE 15 LOGGING IN 15 LOGGING OUT 15 USING TUTORIAL AND HELP 16 CONFIGURING NETWORK SETTINGS 16 IP Settings 17 Wireless LAN Settings 18 Wireless Secu...

Page 3: ...rt for RealPort 37 Adding a Virtual COM Port using RealPort 38 Removing a Virtual COM Port using RealPort 38 Updating RealPort 39 APPENDIX A DEFAULT CONFIGURATION SETTINGS 41 APPENDIX B PRODUCT SPECIFICATIONS 43 APPENDIX C LWS300A DIMENSIONAL DIAGRAM 45 APPENDIX D RS 232 RS 422 RS 485 CONNECTIONS 47 iv Manual Documentation Number LWS300A 1105m Table of Contents Black Box Corporation 1000 Park Driv...

Page 4: ... Management Protocol SNMP is supported Configuration is accomplished through a web based user interface Introduction 2 Manual Documentation Number LWS300A 1105m pn7008 rev000 Chapter 1 Black Box Corporation 1000 Park Drive Lawrence PA 15055 1018 www blackbox com Tech Support and Ordering 724 746 5500 Fax 724 746 0746 Features Wireless networking at up to 11 Mbps on the 2 4 GHz band as specified by...

Page 5: ...ration 1000 Park Drive Lawrence PA 15055 1018 www blackbox com Tech Support and Ordering 724 746 5500 Fax 724 746 0746 802 11 Wireless Networking Basics LWS300A wireless serial servers allow you to connect non network enabled serial devices into a wireless network giving you the capability to gather more data and implement remote programming and management Serial devices no longer are limited to a...

Page 6: ...istens for traffic on the radio carrier frequency and sends data packets if the frequency is clear If the receiving station receives the packet intact it sends an acknowledgement ACK to confirm the packet has been received If the transmitting station does not receive an ACK it assumes a collision occurred and transmits again after a random delay period Communication distances vary depending on the...

Page 7: ...0746 Indicators Switches and Connectors Power LED When DC power has been applied between 10 VDC and 30VDC the red power LED is illuminated Link Integrity LED When the yellow LED is illuminated it indicates that a connection link integrity has been established between the serial server and an access point If this LED is blinking slowly the LWS300A is in ad hoc mode If this LED is blinking quickly t...

Page 8: ... Hardware A typical connection for the LWS300A Wireless Serial Server is infrastructure mode operation in which the LWS300A communicates with a PC on a wired network via an access point which is often a wireless switch or router Figure 2 Connection via the Wireless LAN Hardware Overview 10 Manual Documentation Number LWS300A 1105m Chapter 2 Black Box Corporation 1000 Park Drive Lawrence PA 15055 1...

Page 9: ...nnect Getting Started 12 Manual Documentation Number LWS300A 1105m Chapter 3 Black Box Corporation 1000 Park Drive Lawrence PA 15055 1018 www blackbox com Tech Support and Ordering 724 746 5500 Fax 724 746 0746 If you are configuring your own access point a wireless switch or router ensure that it is configured as a DHCP server with the Wireless Network Name SSID Connect 4 Get the IP Address Use t...

Page 10: ...n or generate an IP address 2 To determine the initial IP address of your LWS300A start the finder exe utility included on the included CD Figure 6 Discovery Utility Dialog 3 The finder exe utility scans the network for devices and then lists each device s IP Address MAC Address Name and Product ID Configuring the LWS300A 14 Manual Documentation Number LWS300A 1105m pn7008 rev000 Chapter 4 Black B...

Page 11: ...accessed the interface for the first time To change usernames and passwords and to add and configure new users see Managing Users and Permissions in Chapter 6 When the username and password are accepted the Configuration and Management Interface homepage will appear Logging Out To log out of the Web Configuration and Management Interface click Logout on the menu bar To finish logging out of the we...

Page 12: ...ply A page will appear asking you to Reboot the LWS300A so that the changes can take effect Using the Web Configuration and Management Interface 18 Manual Documentation Number LWS300A 1105m pn7008 rev000 Chapter 5 Black Box Corporation 1000 Park Drive Lawrence PA 15055 1018 www blackbox com Tech Support and Ordering 724 746 5500 Fax 724 746 0746 Wireless LAN Settings The Wireless LAN Settings sect...

Page 13: ...nnection Typically these setting will not need to be changed Access the online Help file for detailed descriptions of these settings Using the Web Configuration and Management Interface 20 Manual Documentation Number LWS300A 1105m pn7008 rev000 Chapter 5 Black Box Corporation 1000 Park Drive Lawrence PA 15055 1018 www blackbox com Tech Support and Ordering 724 746 5500 Fax 724 746 0746 Configuring...

Page 14: ...ion and Management Interface 22 Manual Documentation Number LWS300A 1105m pn7008 rev000 Chapter 5 Black Box Corporation 1000 Park Drive Lawrence PA 15055 1018 www blackbox com Tech Support and Ordering 724 746 5500 Fax 724 746 0746 TCP Sockets Select TCP Sockets to implement Direct IP Mode using TCP When using TCP Sockets your serial server can be configured as a TCP server or TCP client TCP Serve...

Page 15: ...ber associated with its serial port After selecting UDP Sockets click Apply to return to the Serial Port Configuration page Select the TCP Server Settings as required by your application Using the Web Configuration and Management Interface 24 Manual Documentation Number LWS300A 1105m pn7008 rev000 Chapter 5 Black Box Corporation 1000 Park Drive Lawrence PA 15055 1018 www blackbox com Tech Support ...

Page 16: ... COM port Using the Web Configuration and Management Interface 26 Manual Documentation Number LWS300A 1105m pn7008 rev000 Chapter 5 Black Box Corporation 1000 Park Drive Lawrence PA 15055 1018 www blackbox com Tech Support and Ordering 724 746 5500 Fax 724 746 0746 Advanced Serial Settings Click the Advanced Serial Settings menu bar to access settings used to fine tune the serial port Typically th...

Page 17: ...estinations allows you to specify where to send alarm notification emails their priority and subject title Type the information into the Mail to email address CC address set the Priority and type in the Subject line To send an SNMP trap select Send SNMP trap to following destination when alarm occurs and type the destination IP address for the SNMP trap Using the Web Configuration and Management I...

Page 18: ...n 1000 Park Drive Lawrence PA 15055 1018 www blackbox com Tech Support and Ordering 724 746 5500 Fax 724 746 0746 Changing the Root Username and Password You may want to change the Root username and password after you have gained access to the Web Configuration and Management Interface To change your username and password click Users under the Configuration menu Follow the prompts to enter a new u...

Page 19: ...ration and Management Interface provides information about the current operational state of the LWS300A Serial Ports The Serial Port Management page displays information on Port number Description Profile and Connections If you click Connections the Port Connections Management page appears displaying information on where the port is Connected From Connected To the Protocol or profile being used an...

Page 20: ...load it to the LWS300A Caution When updating the firmware check the support site and release notes for more information to determine if the LWS300A must update the POST before updating the firmware Factory Default Settings The Factory Default Settings page allows you to reset the LWS300A to factory defaults see Appendix A with the option of keeping network settings as they are Caution Restoring th...

Page 21: ...twork page displays statistics related to IP TCP UDP and ICMP protocol activities Figure 16 Network Information Page Using Administrative Features 36 Manual Documentation Number LWS300A 1105m Chapter 7 Black Box Corporation 1000 Park Drive Lawrence PA 15055 1018 www blackbox com Tech Support and Ordering 724 746 5500 Fax 724 746 0746 Reboot The Reboot page allows you to reboot the LWS300A If you c...

Page 22: ...eck the Profile for the port If it is not RealPort click Port 1 4 On the page that appears click Change Profile 5 On the Select Port Profile page select RealPort then click Apply Using RealPort 38 Manual Documentation Number LWS300A 1105m Chapter 8 Black Box Corporation 1000 Park Drive Lawrence PA 15055 1018 www blackbox com Tech Support and Ordering 724 746 5500 Fax 724 746 0746 Adding a Virtual ...

Page 23: ...nish Windows 98 ME NT 4 0 1 Follow the readme txt included with each O S on the CD no setup exe available Updating RealPort Windows 2000 XP 1 Locate the RealPort driver software on the CD you received with your LWS300A 2 Find the RealPort setup exe file for your operating system 3 Start the setup exe file The RealPort Setup Wizard Welcome dialog appears 4 Select the Update RealPort Software then c...

Page 24: ... C Co on nf fi ig gu ur ra at ti io on n S Se et tt ti in ng gs s Server Name LWS300A Username root Password dbps DHCP Enabled Baud Rate 9600 Data Stop 8 1 Parity None Flow Control None TCP UDP Protocol TCP Connection Mode TCP Socket TCP UDP port 2001 Default Configuration Settings 42 Manual Documentation Number LWS300A 1105m Appendix A Black Box Corporation 1000 Park Drive Lawrence PA 15055 1018 ...

Page 25: ...ncluded Protocols Supported TCP UDP DHCP SNMP SSL TLS TELNET RLOGIN RFC 2217 LPD HTTP HTTPS SMTP ICMP IGMP ARP Product Specifications 44 Manual Documentation Number LWS300A 1105m Appendix B Black Box Corporation 1000 Park Drive Lawrence PA 15055 1018 www blackbox com Tech Support and Ordering 724 746 5500 Fax 724 746 0746 Serial Connector 9 pin D type male DB 9M RS 232 Interface Lines Supported TD...

Page 26: ...46 5500 Fax 724 746 0746 A Ap pp pe en nd di ix x C C L LW WS S3 30 00 0A A D Di im me en ns si io on na al l D Di ia ag gr ra am m Figure 17 Dimensional Diagram of the LWS300A Dimensional Diagrams 46 Manual Documentation Number LWS300A 1105m Appendix C Black Box Corporation 1000 Park Drive Lawrence PA 15055 1018 www blackbox com Tech Support and Ordering 724 746 5500 Fax 724 746 0746 ...

Page 27: ...it Data TXD Out 4 Data Terminal Ready DTR Out 5 Signal Ground GND 6 Data Set Ready DSR In 7 Request To Send RTS Out 8 Clear To Send CTS In 9 Not connected NA NA Figure 18 RS 232 Connections in a DB 9 Connector RS 232 RS 422 RS 485 Connections 48 Manual Documentation Number LWS300A 1105m Appendix D Black Box Corporation 1000 Park Drive Lawrence PA 15055 1018 www blackbox com Tech Support and Orderi...

Page 28: ...TY Model Numbers LWS300A Description 1 Port 802 11b Wireless Serial Server Type Light industrial ITE equipment Application of Council Directive 89 336 EEC Standards EN 55022 EN 61000 6 1 EN 61000 4 2 4 3 4 4 4 5 4 6 4 8 4 11 RS 232 RS 422 RS 485 Connections 50 Manual Documentation Number LWS300A 1105m Appendix D Black Box Corporation 1000 Park Drive Lawrence PA 15055 1018 www blackbox com Tech Sup...

Reviews: