CHAPTER 1: Specifications
9
Composite
Sync Data
DBA Max
Maximum
Rate
Rate
Sync Rate
Async Rate
----------------------------------------------------------------------------
64000
1200
14400
38400
2400
14400
3600
19200
4800
19200
7200
19200
9600
19200
12000
28800
14400
28800
19200
33600
28800
38400
33600
48000
38400
56000
46400
56000
48000
63200
51200
63200
56000
63200
57600
63200
----------------------------------------------------------------------------
72000
1200
14400
38400
2400
14400
with 8-bit data
3600
19200
4800
19200
7200
19200
9600
19200
57600
12000
28800
with 7-bit data
14400
28800
19200
33600
28800
38400
33600
48000
38400
56000
46400
56000
48000
64000
51200
64000
56000
71200
57600
71200
64000
71200
Indicators —
Self-test, EEPROM test, local and
remote data loopback tests, and local and
remote composite loopback tests
Power Requirements —
100-250 VAC, @ 0.9A, 50-
60Hz
Power Supply —
External, provided with the
Multiserver
Size —
11.25
″
L
×
8.5
″
W
×
3
″
H (29
×
22
×
8 cm)
Weight —
3.4 lb. (1.5 kg)
Operating Environment —
Temperature:
32 to 114° F (0 to 45.5° C)
operating; -40 to 158° F (-40 to 70° C) storage
Relative Humidity:
25% to 75%
Atmospheric Pressure:
12.47 to 15.37 psi (86 KPA
to 106 KPA)
Agency Compliance
FCC Part 15, Class A
FCC Part 68
C.R.C., C. 13744
VDE 0871 Level B
CSA Standard C.22.2 No. 950 M-89
UL 1950
BABT 340, Issue 6
TÜV/GS-EN 60950/VDE 0805
DOC CS-03