MULTISERVER 500
60
be carried out by a qualified technician.
Wires used for this purpose must be
UL
®
type CM, 22/24 AWG, 4-conductor.
Insert each cable lead into the cutout at the front of
the plug and secure it at the top with a small flat-
head screwdriver. We recommend that you color-
code the cable leads for easy identification.
To make the connection, first remove the female
plug. Then insert each cable lead into the cutout on
the opening at the front of the plug, and secure it at
the top with a screwdriver (see Figure A-4). Finally,
reinsert the plug in the terminal block.
After you make the connection, install the
connector cover: Insert the right tab of the cover in
the retaining slot of the voice/fax interface card’s
4
SG
3
—
2
R
1
T
Insert
Cable
Lead Here
Terminal
Block
Back Panel of
Interface Module
Modular
Cable
Secure Cable
Leads
Here (4 Places)
Terminal
Block Plug
Right
Tab
Connector Cover
Figure A-4. Cable Connections.