Layer 1 Hardware
This option allows the reporting level for layer 1 to be selected. The options are OFF and
ASCII Short Display.
Layer 2 Data Link
This option allows the reporting level for layer 2 to be selected.
The options are OFF, HEX Display, ASCII Short Display and ASCII Long Display.
Layer 3 Call Control
This option allows the reporting level for layer 3 to be selected. The options are OFF, HEX
Display, ASCII Short Display and ASCII Long Display.
Channel Filter
This option brings up a menu, which allows reporting for individual basic rate and primary
rate interfaces to be enabled/disabled.
Call Reference Filter
This option allows reporting at layer 3 to be limited to a single call reference. Use <SPACE>
to disable the call reference filter.
Analyser Specification
This option tells the analyser which protocol it should assume when decoding the messages.
The protocols that can be decoded are CCITT (general purpose), BTNR191 (UK), AT&T
5ESS (USA), NT DMS100 (USA), National ISDN 1 (USA), 1TR6 (Germany) and VN2/3
(France), ETSI (Europe).
Activate Analyser
This option clears the screen and activates the analyser. To exit analyser mode press <esc>.
See the “Protocol Analyser” chapter for a description of the analyser trace display and the
commands that can be used to scroll through the trace.