43
CHAPTER 5: Operation
NOTES (continued)
When switching and reboot operations are initiated, boot/sequence
delay times will be applied as described in Section 4.3.2.
To switch plugs, or to initiate a boot cycle, proceed as follows:
1. Switch plug(s) on: To power on a plug, type
/ON
n
and press
Enter
(where
n
is the number or name of the desired plug).
For example:
/ON 1
or
/ON ROUTER
2. Switch plug(s) off: To power off a plug, type
/OFF
n
and press
Enter
(where
n
is the number or name of the desired plug).
NOTE
The
/OFF
command can also be entered as
/OF
. For example:
/OFF 2
or
/OF ROUTER
3. Boot plug(s): To initiate a boot cycle, type
/BOOT
n
and press
Enter
(where
n
is the number or name of the desired plug).
NOTE
The
/BOOT
command can also be entered as
/BO
. For example:
/BOOT 1
or
/BO ATMSWTCH
4. Set plugs to power up defaults: Type
/D
and press
Enter
. Plugs will be set to
their default on/off status, which is defined using the Plug Parameters menu
(see
Section 4.3.2
).
NOTES
When you have accessed command mode using the system password,
the Default command will be applied to all plugs.
When you have accessed command mode using a plug (user) password,
the Default command will only be applied to the plugs permitted by the
password.
Summary of Contents for PS580A