RACKMOUNT REMOTE POWER MANAGER USER’S MANUAL
4. Set your communication program for ASCII mode, then use the program’s
Send File function to transfer the upgrade file to the power manager. Select
ASCII format, then specify the filename and directory location where the
firmware upgrade file resides.
5. If the upload is successful, the power manager will load the upgrade firmware
into memory and then reboot itself.
NOTE
If you are performing the upgrade procedure via the network port, the
power manager will break the network connection when the system is
reinitialized. However, the power manager will retain the current settings
for the IP address, the Telnet port number, the Web server port number,
and the console port mode and baud rate.
6. Incomplete upload: If the upload is interrupted, times-out, or if the update
file becomes corrupted during transfer, the power manager will display a
screen that asks for confirmation before proceeding. To proceed, type
1
and
press
Enter
, then return to step 4 (above) to retry the upload, or press
Esc
to
reboot the power manager.
7. Recovery mode: In the rare event that the power manager’s operating system
becomes corrupted during installation, front panel indicators will blink, and
the power manager will automatically switch to recovery mode. If the power
manager switches to recovery mode, first access the power manager’s
command mode to reset the console port to 9600 bps, 8 data bits, no parity,
one stop bit, and then return to step 3 (previous page) and repeat the upload
procedure.