External alarm input cable (optional accessory)
Part number
50248000
Use
If the system detects an alarm signal, the external alarm signal con-
nection prevents the use of the driving functions.
Examples for the external alarm signal uses are connections to:
• The reservoir level switch
• The hydraulic fluid temperature switch
• The overpressure switch.
Cable type
Straight
1
2
Length
1 m
Head 1 design
Deutsch DT06-6S connector that connects to the control device
Head 2 design
Free conductors to connect to the alarm input circuit.
Wiring
Red – supply for circuit (12 V)
Black – signal (0 / 12 V)
Brown – ground
The signal that you connect must be of a binary type (on / off). The con-
nected signal can be either:
• Normally low (0 V) signals
• Normally high (12 V) signals.
The figure shows an example of a connection of an electronic switch to
the alarm input cable. For the correct connections to use in your system,
refer to the technical data of the devices that you have.
1
2
S
L+
L-
5.3.14
Control system
Product manual
27