MAJOR GENERATOR FEATURES
CONTROL PANEL
A. 120 V, 20 Ampere Duplex Receptacle
20 amps of current may be drawn from each half of the recep-
tacle. However, total power drawn must be kept within nameplate
ratings. These receptacles may be used along with the twistlock re-
ceptacle provided the generator is not overloaded.
B. 120/240 V, 30 Ampere Twistlock Receptacle
A maximum of 30 amps may be drawn from the 120/240 volt
receptacle, provided it is the only receptacle used. However, current
must be limited to the nameplate rating. If the 120/240 volt recep-
tacle is used along with the 120 volt receptacle, the total load drawn
must not exceed the nameplate ratings.
C. Circuit Breakers
The receptacles are protected by an AC circuit breaker. If the
generator is overloaded or an external short circuit occurs, the circuit
breaker will trip. If this occurs, disconnect all electrical loads and
try to determine the cause of the problem before attempting to use
the generator again. If overloading causes the circuit breaker to trip,
reduce the load.
NOTE: Continuous tripping of the circuit breaker
may cause damage to generator or equipment.
The circuit breaker
may be reset by pushing the button of the breaker.
D. Cord Retainer
The cord retainer is used to prevent plugs from being pulled out
of the 120-volt receptacles.
E. Analog Hour Meter
Honda GX390 engine
—
390 cc
Cast-iron cylinder sleeve
Low lubricant alert system
Receptacles on control panel
Cord Retainers
Automatic voltage regulator (AVR)
8 gallon metal fuel tank
Analog Hour Meter
Portability Kit