If your compressor does not start

•  Check that you have plugged the power lead into a 

standard 240V 10Amp power point and turned the 

switch ON.

•  Check that you have turned the air compressor ON/

OFF switch ON.

•  The air tank may be full.  Use your air tool and the air 

compressor should start when the pressure decreases 

to 85PSI.

If your compressor does not build up pressure

•  Check that the tank drain tap is sealed.

If your compressor smells like burnt oil

•  Check the oil level as it may be low

If these tips do not work please have your unit checked by 

an authorised service centre.
Call BLACKRIDGE for your closest centre, 

Aust. 1300 660 457 

N.Z. 0800 474 876 

PIC. 14

MAINTENANCE

Daily: Before use

1. Seal the tank drain tap, see Pic.13.
2. Check the oil level, see page 10, Pic. 4.
3. Check safety valve operation, see page 16, Pic.12 

After use

1. Open the tank drain tap, see Pic.13.
2. Wipe down the air compressor.
3. Store safely and securely.

Every 50 Hours:

1. Replace the air filter.
2. Drain oil completely and replace with fresh oil.

To drain;

a.   Loosen and remove the drain bolt, Pic. 14 and 

drain oil into a funnel / bottle and dispose of in an 

appropriate manner.

b.   Once drained replace and tighten the drain bolt.
c.   Wipe up any oil spills.
d.   Fill up to the top red dot on the sight glass with fresh 

clean oil.  Refer page 10 for “To Add Oil, if Required” 

details.  Refer to diagram Pic. 4, page 10.

NOTE:  Use oil type SAE30.

Remove oil drain 

bolt and drain 

used oil into 

funnel. Replace 

and tighten oil 

drain bolt

TROUBLE SHOOTING

Summary of Contents for BR105D

Page 1: ...arts or product information please contact Smart Marketing Group Pty Ltd AUST 1300 660 457 N Z 0800 474 876 Recyclable Cardboard Portable compressor for general light duty task around the home MODEL N...

Page 2: ...ed air tools and accessories above are not included with this air compressor Section Page Contents 2 Suggested Applications 2 Introduction 3 Guarantee 3 4 General Safety Instructions 5 7 Electrical In...

Page 3: ...f the product with parts and components of similar quality grade and composition where an identical part or component is not available Products presented for repair may be replaced by refurbished prod...

Page 4: ...where an identical part or component is not available Products presented for repair may be replaced by refurbished products of the same type rather than being repaired Refurbished parts may be used to...

Page 5: ...for use by young children or infirm persons without supervision The air compressor and tools should be kept out of reach of children preferably stored or locked in a secure cabinet or room when not i...

Page 6: ...dust at all times Blocked ventilation slots can cause overheating and damage to the motor DISCONNECT AIR COMPRESSOR Ensure that the air compressor is disconnected from the mains supply when not in us...

Page 7: ...o not have safety lenses Footwear Where there is the risk of heavy objects or if there is a risk of slipping on wet or slippery floors suitable non slip safety footwear should be worn Protect your fee...

Page 8: ...re that the air compressor is disconnected from the mains supply when not in use before servicing lubricating making changes and when changing attachments such as air hoses tools Always use the correc...

Page 9: ...n tap 8 Rubber stopper 9 Safety Valve 10 Tank pressure gauge large 11 Front handle 12 Pressure switch 13 On Off button red colour 14 Outlet pressure gauge small 15 Air outlet nitto style socket 16 Out...

Page 10: ...nd up about 20cm hold for about 1 minute and place back on ground Look at the sight glass and ensure the oil is above the red dot on the sight glass as per the OIL LEVEL GAUGE label see Pic 3 and Pic...

Page 11: ...the bracket located on the bottom of the tank 1 Undo the nut and remove the washer 2 Push through the bracket and replace the washer 3 Tighten the nut Pic 5 WHEELS 1 Insert a bolt through the wheel 2...

Page 12: ...y warranty To turn your air compressor ON Lift up the red ON OFF switch on top of the pressure switch To turn your air compressor OFF Push down the red ON OFF switch on top of the pressure switch AIR...

Page 13: ...inflator does not get covered in dust or paint use a longer air hose to ensure inflator is in clean air USING THE AIR COMPRESSOR Before starting run through this simple list 1 Transport plug removed...

Page 14: ...the power lead 3 Disconnect your air tools and air hose 4 Clean your air hose and air tools 5 Store your air hose and air tools in a secure well ventilated cabinet 6 Slowly open the tank drain tap se...

Page 15: ...t the correct working pressure Note Different air tools require different operating pressures Always check with the tool manufacturer if unsure SAFETY VALVE Pic 11 NOTE When checking the safety valve...

Page 16: ...lots are kept clean and free from dust dirt build up STORAGE When storing ensure the air tank has been emptied as per Drain Tap above Always store away from children preferable in a locked room Drain...

Page 17: ...4 876 PIC 14 MAINTENANCE Daily Before use 1 Seal the tank drain tap see Pic 13 2 Check the oil level see page 10 Pic 4 3 Check safety valve operation see page 16 Pic 12 After use 1 Open the tank drain...

Page 18: ...sher 2 95 BRC95RS Part Description Qty SMG Part No 14 Screw 2 95 BRC95RS 15 Unloading Tube Nut 2 95 BRC95UT 15 Unloading Tube 1 95 BRC95UT 19 Safety Valve 1 95 BRC95SPV 20 Pressure Gauge Large 1 95 BR...

Page 19: ...19 NOTES...

Page 20: ...equired to make any claims under the 12 month warranty Specifications Air Compressor BR105D Voltage 240V AC 50Hz Motor Electric 2 HP Wattage 1500W No Load Speed 2800 RPM FAD Free Air Delivery 105L per...

Reviews: