14
15
PRE-OPERATION FINAL CHECKS
You have now fully assembled your Briggs and Stratton
powered air compressor.
To ensure all is good for your initial run just take a minute to
ensure the following.
1. Check that all bolts are tight.
2. Check that both caster wheels are sitting level on the
ground.
3. The fuel tap is OFF
4. The engine switch is OFF.
5. Check that the spark plug lead is firmly attached to the
top of the spark plug.
6. Holding on to the belt cage gently rock the air
compressor and listen for any noise which may indicate
loose items. If anything appears to be loose either
tighten or consult a service agent.
Initial Run
To ensure your Briggs and Stratton powered air compressor
is fully lubricated please go through this initial run. This
run is recommended when new and if you have not used
your Briggs and Stratton powered air compressor for over
6 months.
Before starting your running in ensure that the
following has been completed:
1. The air compressor has been fully assembled, see pages
10 – 11.
2. Pump oil level is correct, see page 12.
3. Engine oil level is correct, see page 13.
4. Fuel tank has been filled with the correct unleaded petrol
(ULP), see page 9.
To run your Briggs & Stratton powered
air compressor;
Note: For full details on starting and stopping your Briggs
and Stratton powered air compressor, see below and
pages 16 – 18.
1. Open the drain tap.
2. Open the unloading valve.
3. Turn the fuel tap on.
4. Turn the choke on.
5. Turn the engine switch on.
6. Using the recoil starter, start you air compressor.
7. Once started turn the choke to off.
8. Run the air compressor for approximately 1 minute,
with everything open this will allow the oil to circulate
fully to ensure the air compressor is fully lubricated
under no load.
After about 1 minute stop the air compressor. Allow to
cool for approximately 10 minutes. Recheck the pump
and engine oil level and top up if needed, additional oil,
SAE30, not included.
To STOP your Briggs & Stratton powered
air compressor;
1. Turn the fuel tap off.
2. Turn the engine switch off.
Before starting your air compressor again
ensure:
1. Tank drain tap is closed.
Note:
1. Always position compressor on level ground.
2. Always position compressor away from work area so
that the compressor does not get covered in dust or
paint - use a longer air hose to ensure compressor is
in clean air.